Oxygenator use in Ventricular Assist Devices from the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) Registry
Said, A. S.; Mehegan, M.; Joong, A.; Morrison, A.; Sutcliffe, D.; Philip, J.; Shezad, M.; Harris, R.; Amidon, M.; Knoll, C.; Wisotzkey, B.; Absi, M.; Wilde, M.; Butto, A.; Dykes, J.; Watanabe, K.; Zinn, M.; May, L. J.; VanderPluym, C.; Braunlin, E.; Castleberry, C.; Deshpande, S. R.; Lorts, A.; Wright, L.; O'Connor, M.; Mokshagundam, D.; Rabinowitz, E.
Show abstract
ObjectiveTo describe the utilization patterns and outcomes of pediatric patients supported with oxygenators during their ventricular assist device (VAD) course. DesignMulti-center, retrospective cohort study using data from the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) registry. SettingData query from the ACTION registry, which collects clinical data on pediatric patients with end-stage heart disease, reported cases of combined oxygenator-VAD use. PatientsSixty-one pediatric patients (27 female) from 21 contributing ACTION centers were supported on oxygenators during their VAD course between 2013-2024. The median age was 272 days (IQR 68-1334), and the median weight was 7.9kg (IQR 4.4-12). The majority had congenital heart disease (CHD), with 66% having single-ventricle pathology. InterventionsNone. Measurement and Main ResultsThe study population demonstrated high illness severity at the time of VAD implant, with 97% requiring inotropic support, 79% requiring mechanical ventilation, and 46% on ECMO. The total median duration of VAD support was 45 days (IQR 16-163). Of the 61 patients, 44% achieved transplant or recovery. The mortality rate was high at 52%, and was associated with younger age, smaller size, CHD and pre-implant use of neuromuscular blocking agents. Adverse events included infection (36%), major bleeding (36%), central nervous system injuries (21%), and dialysis (20%). None demonstrated clinically significant association with oxygenator support timing, but mortality was associated with higher adverse events rates, particularly pulmonary hemorrhage, dialysis, and infections (especially mediastinitis). ConclusionPediatric patients requiring oxygenators during VAD therapy exhibit high illness severity and frequent adverse events. Mortality is high and associated with younger age, smaller size, CHD, pre-implant use of neuromuscular blocking agents as well frequency of on-device adverse events, particularly pulmonary hemorrhage, dialysis, and infections. Oxygenator support likely reflects disease severity rather than directly contributing to mortality. Further investigation is needed to optimize patient selection and management strategies. Research In ContextO_LIOver the past two decades, pediatric VAD utilization has increased. Support from collaborative networks like ACTION has enabled investigation of nuanced strategies, such as temporary oxygenator use, providing a platform to evaluate feasibility, safety, and patient-specific considerations across diverse populations. C_LIO_LIIn adult populations, oxygenator use alongside VADs has been employed for respiratory failure, ARDS, RV support, and as a bridge to lung transplant or transition from ECMO. However, these strategies have not been systematically studied in pediatric cohorts until now. C_LIO_LIThis study presents the most comprehensive review of pediatric (or adult) oxygenator-VAD support to date, characterizing patient populations, utilization patterns, and associated outcomes. It provides foundational data for guiding future research into management strategies in this high-risk group. C_LI At the BedsideO_LIPediatric patients requiring oxygenator support during VAD therapy were typically younger, smaller, and had complex congenital heart disease, particularly single-ventricle physiology. These characteristics were associated with higher mortality and reflect a population with profound critical illness at baseline. C_LIO_LIThis cohort experienced high rates of adverse events, including major bleeding, infections, dialysis, and neurologic injury. While oxygenator timing was not independently associated with outcomes, mortality exceeded 50% and was linked to complications such as dialysis, pulmonary hemorrhage, and infections. C_LIO_LIClinicians should view oxygenator-VAD support as a surrogate marker for extreme illness severity rather than a direct contributor to poor outcome. This study highlights the need for tailored management strategies and informs clinician and family decision-making in this high-risk population. C_LI
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Prognostic Value of Patient-Reported Outcomes in Predicting Long-term Mortality after Transcatheter Aortic Valve Replacement (TAVR) 95%
- Effectiveness of an Impella versus intra-aortic balloon pump in patients who received extracorporeal membrane oxygenation 94%
- Trends in Gaps of Care for Congenital Heart Disease Patients: Implications for Social Determinants of Health and Child Opportunity Index 93%
Similar papers in this journal
- Arterial Oxygen and Carbon Dioxide Tension and Acute Brain Injury in Extracorporeal Cardiopulmonary Resuscitation Patients: Analysis of the Extracorporeal Life Support Organization Registry 92%
- Advanced Hemodynamic and Cluster Analysis for Identifying Novel RV function subphenotypes in Patients with Pulmonary Hypertension 91%
- CT-based Machine Learning for Donor Lung Screening Prior to Transplantation 90%
Similar papers in this journal
- Trends in Mechanical Circulatory Support utilization, Left Ventricular Assist Device implantation and Transplant during Cardiogenic Shock Hospitalizations, after the New Heart Allocation Policy 97%
- Inpatient Outcomes Of Mechanical Circulatory Support Devices and Bridging to Transplantation in Hypertrophic Cardiomyopathy 96%
- Early left ventricular systolic function is a more sensitive predictor of adverse events after heart transplant 92%
Similar papers in this journal
- Diastolic Perfusion Pressure Predicts Response to Inotropes/Vasopressors and Benefit from Mechanical Circulatory Support in Cardiogenic Shock? 96%
- Impact of Advanced Therapy Centers on Characteristics and Outcomes of Heart Failure Admissions 94%
- Prediction of donor heart acceptance for transplant and its clinical implications – results from the Donor Heart Study 93%
Similar papers in this journal
- Predictors of successful weaning from Veno-Arterial Extracorporeal Membrane Oxygenation (V-A ECMO): A Systematic Review and Meta-analysis 94%
- Impact of left ventricular assist devices and heart transplant on acute myocardial infarction and heart failure mortality and readmission measures 94%
- Effects of low versus high inspired oxygen fraction on myocardial injury after transcatheter aortic valve implantation: A randomized clinical trial 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.