A Numerical Alternative to MR Thermometry for Safety Validation of Multi-Channel RF Transmit Coils
Sadeghi-Tarakameh, A.; Schmidt, S.; Waks, M.; Lagore, R. L.; Grant, A.; Auerbach, E.; DelaBarre, L.; Knudsen, L.; Lenglet, C.; Vizioli, L.; Yacoub, E.; Adriany, G.; Metzger, G. J.; Ugurbil, K.; Eryaman, Y.
Show abstract
PurposeThis study proposes an alternative approach to MR thermometry (MRT) for the safety validation of multi-channel RF transmit coils and demonstrates its use to enable human studies at 10.5T. MethodsTo ensure patient safety, specific absorption rate (SAR) limits established under international guidelines must not be exceeded. Predicting SAR on state-of-the-art parallel transmit systems relies on electromagnetic simulations, which require extensive experimental validation. Despite a well-established validation workflow, SAR prediction errors are unavoidable and must be quantified as a safety margin. While MRT tests are commonly used for this purpose, their technical challenges necessitate an alternative. The proposed technique propagates the error between experimentally and numerically acquired B+distributions to the uncertainty in simulated peak local SAR using Monte-Carlo simulations without the need for MRT. This method was validated using a 16-channel transceiver coil for imaging the human torso (henceforth referred to as a "body" coil) at 10.5T with two excitation scenarios, as well as an 8-channel 10.5T head coil with four excitation scenarios. ResultsThe proposed numerical technique proved more conservative than existing MRT-based SAR error quantification methods across all tested scenarios. Its application to validate three state-of-the-art head coils (16Tx/32Rx, 16Tx/80Rx, and 16Tx/128Rx) led to regulatory approval for human head imaging and high-quality functional as well as diffusion MRI results at 10.5T. ConclusionA numerical alternative to MRT requires only the experimental acquisition of B+ maps for comparison with simulations, enabling the quantification of uncertainty in SAR prediction. This technique was applied to three 16-channel transmit arrays, each used in conjunction with high-channel-count receive arrays for in vivo imaging.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A 48-Channel Receive Array Coil for Mesoscopic Diffusion-Weighted MRI of Human ex vivo Brain Imaging on the 3T Connectome Scanner 96%
- On the Reconstruction of Magnetic ResonanceCurrent Density Images of the Human Brain:Pitfalls and Perspectives 93%
- Fast computational optimization of TMS coil placement for individualized electric field targeting 93%
Similar papers in this journal
- Impact of Focused Ultrasound on the Cellular Network of Liver Tissue: A New Perspective for Thermal Lesion Detection 91%
- An Adaptive H-Refinement Method for the Boundary Element Fast Multipole Method for Quasi-static Electromagnetic Modeling 91%
- Reproducible spectral CT thermometry with liver-mimicking phantoms for image-guided thermal ablation 91%
Similar papers in this journal
Similar papers in this journal
- Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T 94%
- Reconfigurable MRI coil technology can substantially reduce RF heating at the tips of bilateral deep brain stimulation implants 92%
- Acceleration of chemical shift encoding-based water fat MRI for liver proton density fat fraction and T2* mapping using compressed sensing 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.