Non-destructive, high-resolution T cell characterization and subtyping via deep-ultraviolet microscopy

Gorti, V.; Serafini, C. E.; Silva Trenkle, A. D.; McCubbins, K.; LeCompte, I.; Kwong, G. A.; Robles, F. E.

2025-05-26 immunology
10.1101/2025.05.20.655120 bioRxiv
Show abstract

T cell characterization is critical for understanding immune function, monitoring disease progression, and optimizing cell-based therapies. Current technologies to characterize T cells, such as flow cytometry, require fluorescent labeling and typically are destructive endpoint measurements. Non-destructive, label-free imaging methods have been proposed, but face limitations with throughput, specificity, and system complexity. Here we demonstrate deep-ultraviolet (UV) microscopy as a label-free, non-destructive, fast and simple imaging approach for assessing T cell viability, activation state, and subtype with high accuracy. Using static deep-UV images, we characterize T cell viability and activation state, demonstrating excellent agreement with flow cytometry measurements. We further apply dynamic deep-UV imaging to quantify intracellular activity, enabling fast and accurate subtyping of CD4+ and CD8+ T cells. These results corroborate recent studies on metabolic activity differences between these subtypes, but now with deep-UV microscopy they are enabled by a non-destructive, fast, low-cost and simple approach. Together, our results demonstrate deep-UV microscopy as a powerful tool for high-throughput immune cell characterization, with broad applications in immunology re-search, immune monitoring, and development of emerging cell-based therapies.

Matching journals

The top 9 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.