Concurrent validity and between-device reliability of the Catapult Vector S8 GNSS device
Ellens, S.; Moran, C.; Varley, M. C.
Show abstract
This study assessed the concurrent validity and between-device reliability of the Catapult Vector S8 GNSS device for measuring distance, speed, acceleration and banded distance metrics. Twelve male sub-elite team sport athletes completed a testing protocol consisting of linear sprints, change of direction drills and a modified small-sided game. Validity was evaluated against criterion reference systems, a VICON motion capture system for most trials and a Stalker ATS radar for 50 m sprints, evaluated using root mean square error (RMSE) and mean bias. Between-device reliability was assessed using interclass correlation coefficients (ICC) and typical error (TE%). The Vector S8 demonstrated good validity with minimal errors for instantaneous distance (RMSE: 0.03 {+/-} 0.01 m), speed (RMSE: 0.14 {+/-} 0.05 ms-1) and acceleration (RMSE: 0.29 {+/-} 0.14 ms-2). No overall bias was detected for instantaneous distance and speed, and the bias for acceleration (-0.016) was minimal. Accumulated distance showed a small underestimation across trials (mean bias -1.42%), with consistently low RMSE values (0.26-3.06 m), indicating high measurement precision. The 50 m sprint results showed similar validity, with minimal RMSE for instantaneous speed (0.14 {+/-} 0.15 ms-1) and acceleration (0.22 {+/-} 0.22 ms-2). Between device reliability demonstrated excellent agreement across all measured variables (ICC [≥] 0.90) with good precision (TE as CV <5%). No significant systematic bias was observed between devices for any variable (p > 0.05). This is the first study to validate the Catapult Vector S8 GNSS device, demonstrating that it is valid and reliable for measuring distance, speed and acceleration during sport-specific movements.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Using dynamic ultrasound to assess Achilles tendon mechanics during running: the effect on running pattern and muscle-tendon junction tracking 96%
- Inter-session repeatability of markerless motion capture gait kinematics 96%
- Firefighter Helmets and Cervical Intervertebral Kinematics: An OpenSim-Based Biomechanical Study 95%
Similar papers in this journal
- Assessing the validity of the zero-velocity update method for sprinting speeds 97%
- Assessing sprint technique with shoe-mounted inertial sensors 97%
- The effects of sport-specific training on individuals action strategies while avoiding a virtual player approaching on a 45{o} angle while completing a secondary task 96%
Similar papers in this journal
Similar papers in this journal
- Joint contact forces during barefoot, minimal and conventional shod running are highly individual 96%
- Muscle activity of cutting manoeuvres and soccer inside passing suggests an increased groin injury risk during these movements 95%
- Quantifying mechanical loading and elastic strain energy of the human Achilles tendon during walking and running 95%
Similar papers in this journal
- Quantifying paddling kinematic through muscle activation and whole body coordination during maximal sprint of different duration on a kayak ergometer: a pilot study 95%
- Successful reboot of high-performance sporting activities by Japanese national women’s handball team in Tokyo, 2020 during the COVID-19 pandemic: An initiative by Japan Sports-Cyber Physical System (JS-CPS) of Sports Research Innovation Project (SRIP) 94%
- Performance and Thermal Perceptions of Runners Competing in the London Marathon: Impact of environmental conditions 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.