Impact of Aortic Valve Leaflets Calcium Volume and Distribution on Post-TAVR Conduction Abnormalities
Reza, S.; Kovarovic, B.; Bluestein, D.
Show abstract
IntroductionTranscatheter aortic valve replacement (TAVR) is increasingly used to treat aortic stenosis, including in low-risk patients. However, post-procedural cardiac conduction abnormalities (CCA), often requiring permanent pacemaker implantation (PPI), remain a concern. This study investigates how the volume and distribution of aortic leaflet calcium deposits influence the risk of post-TAVR CCA. MethodsAn electromechanically coupled four-chamber beating heart model was used to simulate TAVR with a self-expandable Evolut(R) 26 mm device. Five virtual patient scenarios were modeled with varying calcium volumes and distributions: no calcium, uniform distribution (3 Calc), and isolated calcification on the left coronary leaflet (LCL), right coronary leaflet (RCL), or non-coronary leaflet (NCL). Electrical conduction was simulated using a monodomain model and coupled with structural mechanics to evaluate tissue-device interactions. Metrics included principal stress, contact pressure, and contact pressure index (CPI) over three cardiac cycles. ResultsLarger calcium volumes and specific leaflet distributions increased stress and contact pressure near the atrioventricular node. The LCL model exhibited the highest mechanical stress and peak contact pressure (13.1 kPa), while the NCL model showed the lowest (6.42 kPa). The RCL model had intermediate values. Elevated contact pressure and stress in the LCL case suggest an increased risk of conduction disruption and PPI. ConclusionLeaflet calcium deposit volume and distribution significantly influence mechanical stress and contact dynamics near the conduction system following TAVR. These insights support the integration of clinical data, such as leaflet calcium volume and distribution into pre-procedural planning to personalize risk assessment and improve patient outcomes. HighlightsO_LIBeating heart model used to assess post-TAVR conduction abnormality risk. C_LIO_LIHigher calcium volume increases contact pressure near conduction pathways. C_LIO_LILeft coronary leaflet calcification linked to elevated post-TAVR CCA risk. C_LIO_LIDynamic simulations show stress fluctuations during cardiac cycles. C_LIO_LIFindings support personalized TAVR planning to reduce PPI need. C_LI
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part I: Establishing Credibility of an Advanced Model 97%
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration 96%
- Computational hemodynamic indices to identify Transcatheter Aortic Valve Implantation degeneration 94%
Similar papers in this journal
- Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm 97%
- Hemodynamics Indicates Differences Between Patients With And Without A Stroke Outcome After Left Ventricular Assist Device Implantation 96%
- Patient-specific analysis of bicuspid aortic valve hemodynamics using a fully coupled fluid-structure interaction (FSI) model 96%
Similar papers in this journal
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 98%
- Impact of residual intimal flap displacement post-TEVAR on TBAD haemodynamics in compliant, patient-specific CFD simulations informed by MRI 97%
- Switching the left and the right hearts: A novel bi-ventricle mechanical support strategy with spared native single-ventricle 96%
Similar papers in this journal
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study. 98%
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 96%
- Ventricular anatomical complexity and gender differences impact predictions from computational models 96%
Similar papers in this journal
- Patient Screening for Self-Expanding Percutaneous Pulmonary Valves using Virtual Reality 96%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 95%
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.