Assessing Ankle Range of Motion with Wearable Technology: A Comparative Accuracy and Reliability Study
Hu, B.; Warsif, s.; Atout, M.; Jabri, A.; Mahmoud, H.; Mahmoud, M.; Patel, d.; Raza, F.; Chomiak, T.
Show abstract
BackgroundAccurate measurement of ankle range of motion (ROM) is essential for diagnosing and treating musculoskeletal conditions, optimizing athletic performance, and managing neurological disorders such as Parkinsons disease. This study evaluates the novel Ambulosono device, a sensor-based tool, against the traditional goniometer for assessing Ankle ROM in healthy participants. MethodsA comparative cross-sectional study was conducted on 54 healthy participants aged 15 to 24 years. Ankle ROM was measured using the goniometer, placed on the lateral malleolus, and the Ambulosono device, secured on the dorsum of the foot. Participants performed maximal dorsiflexion and plantarflexion with knees extended, and five measurements were taken per device on both feet in randomized order. Statistical analyses included descriptive statistics, Bland-Altman plots, and Intraclass Correlation Coefficients (ICCs) to assess agreement and reliability. ResultsMean goniometer ROM was 58.44{degrees} (SD=5.54) versus Ambulosonos 56.80{degrees} (SD=3.88). No significant differences emerged between devices, foot sides, or gender. Bland-Altman analysis indicated agreement without P proportional bias. Reliability was excellent (Cronbachs alpha=0.983, ICC=0.983). ConclusionThe Ambulosono device is a robust tool that offers a reliable alternative to traditional goniometry, with advantages such as real-time feedback and reduced inter-rater variability. Its potential applications extend beyond clinical and athletic settings to include neurological rehabilitation and remote patient monitoring. Further research is warranted to validate its efficacy across diverse populations and real-world scenarios.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- The Investigation of Nonlinear Variability Underlying Postural Control in The Injure-Limb in Individuals with and without Chronic Ankle Instability 97%
- Clinical measures of balance and gait cannot differentiate somatosensory impairments in people with lower-limb amputation 96%
- Predicting vertical and shear ground reaction forces during walking and jogging using wearable plantar pressure insoles 96%
Similar papers in this journal
- Assessing sprint technique with shoe-mounted inertial sensors 97%
- Intra- and inter-rater reliability, agreement, and minimal detectable change of the handheld dynamometer in individuals with symptomatic hip osteoarthritis 96%
- Biomechanical effects of adding an articulating toe joint to a passive foot prosthesis for incline and decline walking 96%
Similar papers in this journal
- Differences in external loads of different pitch types in Chinese male college baseball players 96%
- Do anthropometric characteristics and physical capacities of highly trained junior badminton players differ according to age and sex? 94%
- Head and body dyskinesia during gait in tactical athletes with vestibular deficit following concussion 94%
Similar papers in this journal
Similar papers in this journal
- Muscle activity of cutting manoeuvres and soccer inside passing suggests an increased groin injury risk during these movements 97%
- Proprioceptive and visual motion detection acuity contribute to children dynamic postural control 96%
- Quantifying mechanical loading and elastic strain energy of the human Achilles tendon during walking and running 96%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.