Back

A novel approach to determine the micromotion of screw-plate interfaces of a locking-type plating system under axial cyclic loading via synchronized digital image correlation

Halbauer, C.; Paech, A.; Capanni, F.

2025-04-14 orthopedics
10.1101/2025.04.11.25325637 medRxiv
Show abstract

ObjectivesA previously published biomechanical study of axial cyclic testing on a lockingtype plating system presented several failure types of the screw-plate interfaces (SPI). It was assumed that increasing micromotions of SPIs result consequently in initial failure of SPIs during cyclic loading. In conclusion, measurements of SPIs via digital image correlation (DIC) were suggested to detect potential micromotions. MethodsDIC measurements were performed using the ARAMIS Adjustable 3D measurement system to track the surface of the screw-head and bone plate during cyclic testing to determine potential micromotions. The micromotion is thereby described as the change in distance of the screw-head center to a reference point on the bone plate, providing information about the quality of interlocking of the related SPI during cyclic loading. Micromotion analysis was performed on the fracture-adjacent SPIs of the implant system, that were considered as the most relevant interfaces. ResultsMicromotion could be detected for both facture-adjacent SPIs in all test samples with increasing magnitude during cyclic testing, resulting in micromotions up to 587 {micro}m for the proximal and 321 {micro}m for the distal fracture-adjacent SPI after 50k load cycles. The strongest increase in micromotion could thereby be detected within early stages of cyclic loading. ConclusionsThe approach to determine micromotions of SPIs during axial cyclic loading was successful, indicating a reduction of the SPI s quality of interlocking as micromotions increase during cyclic loading of the tested locking-type implant system.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
PLOS ONE
4510 papers in training set
Top 11%
15.2%
2
Scientific Reports
3102 papers in training set
Top 2%
15.2%
3
Applied Sciences
24 papers in training set
Top 0.1%
12.8%
4
Computational and Structural Biotechnology Journal
216 papers in training set
Top 0.5%
6.6%
5
Annals of Biomedical Engineering
34 papers in training set
Top 0.1%
5.0%
50% of probability mass above
6
Medical Physics
14 papers in training set
Top 0.1%
4.5%
7
Cureus
67 papers in training set
Top 1%
3.7%
8
Journal of Orthopaedic Research
19 papers in training set
Top 0.1%
3.2%
9
BMJ Open
554 papers in training set
Top 7%
2.8%
10
Journal of Clinical Medicine
91 papers in training set
Top 2%
2.1%
11
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 0.9%
2.1%
12
Journal of the Mechanical Behavior of Biomedical Materials
22 papers in training set
Top 0.1%
1.8%
13
Bioengineering
24 papers in training set
Top 0.4%
1.8%
14
Acta Biomaterialia
85 papers in training set
Top 0.6%
1.4%
15
Royal Society Open Science
193 papers in training set
Top 3%
1.4%
16
Biofabrication
32 papers in training set
Top 0.6%
1.3%
17
Frontiers in Human Neuroscience
67 papers in training set
Top 2%
1.3%
18
Frontiers in Immunology
586 papers in training set
Top 5%
1.3%
19
JBMR Plus
16 papers in training set
Top 0.2%
1.3%
20
JMIR Medical Informatics
17 papers in training set
Top 1%
0.9%
21
Bone
22 papers in training set
Top 0.4%
0.8%
22
Sensors
39 papers in training set
Top 2%
0.8%
23
Frontiers in Physiology
93 papers in training set
Top 6%
0.7%
24
PeerJ
261 papers in training set
Top 17%
0.7%
25
Peer Community Journal
254 papers in training set
Top 5%
0.5%