Agreement on Respiratory Impedance Measured by Two Commercial Forced Oscillation Technique Devices: A Randomized Crossover Study
De, S.
Show abstract
BackgroundThe performance of forced oscillation technique (FOT) devices may vary due to differences in hardware and signal processing. Research questionDoes the respiratory impedance (Zrs) measured by two commercial FOT devices agree? Study Design and MethodsThe Zrs of 97 consecutive adults with respiratory symptoms were measured using TremoFlo(R) C-100 and Resmon Pro FULL V3, employing a random allocation and crossover design. The parameters between the devices were compared using paired t-tests and Bland-Altman plots with 95% limits of agreement (LoA). ResultsThe average age of the study population was 42.3 years, with 46% were women. The resistance parameters (R5 and R19) of Resmon were larger than those obtained with TremoFlo(R). However, R5-19 of Resmon was significantly smaller than TremoFlo(R), with a paired difference of -0.20 cm H2O/L/s (95% CI: -0.35, -0.05; p = 0.01). The within- and whole-breath X5 of Resmon were significantly less negative than those obtained with TremoFlo(R). The reactance area and resonant frequency of Resmon were also significantly smaller than those obtained with TremoFlo(R). The bias for R5 (Bias: 0.29 cmH2O/L/s; LoA: - 2.69, 3.26) was broad and had random errors. The bias for X5 (bias: 0.8 cmH2O/L/s; 95% LoA: -1.25, 2.85) and Ax (Bias: -13.66 cmH2O/L/s; LoA: -45.46, 18.14) was also wide and exhibited systematic errors. InterpretationsRespiratory impedance measured by the two FOT devices differed significantly, particularly for the reactance parameters. Normative Zrs generated by a particular oscillometer should be avoided when interpreting reports obtained from another device.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Performance of EasyBreath ® Decathlon Snorkeling mask for Delivering Continuous Positive Airway Pressure 96%
- A Cross-sectional Feasibility Study to Evaluate the Usability and Efficacy of “Swaasa”: An AI-Platform for Rapid Respiratory Health Assessment 93%
- Kinematic signature of high-risk labored breathing revealed by novel signal analysis 93%
Similar papers in this journal
- Performance of popular pulse oximeters compared with simultaneous arterial oxygen saturation or clinical-grade pulse oximetry: a cross-sectional validation study in intensive care patients 93%
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 93%
- Remote-management of COPD: Evaluating Implementation of Digital Innovation to Enable Routine Care (RECEIVER) – Protocol for a feasibility and service adoption observational cohort study 91%
Similar papers in this journal
- The Effect of a Post-Bronchodilator FEV 1 /FVC < 0.7 on COPD Diagnosis and Treatment: A Regression Discontinuity Design 90%
- Perfusion imaging heterogeneity during NO inhalation distinguishes pulmonary arterial hypertension (PAH) from healthy subjects and has potential as an imaging biomarker 90%
- Airway expression of SARS-CoV-2 receptor, ACE2, and proteases, TMPRSS2 and furin, in severe asthma 90%
Similar papers in this journal
- Optimised oxygenation improves functional capacity during daily activities in patients with COPD on long-term oxygen therapy – a randomised crossover trial 94%
- Aerosol emission from the respiratory tract: an analysis of relative risks from oxygen delivery systems 92%
- Day-to-day Variability Indices improve utility of Oscillometry in Paediatric Asthma 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.