Interethnic Validation of Artificial Intelligence for prediction of Atrial Fibrillation Using Sinus Rhythm Electrocardiogram
Lee, J. H.; Kim, J.; Choi, J.; Choi, Y. Y.; Oh, I.-Y.; Cho, Y.
Show abstract
BackgroundPrevious research has demonstrated acceptable diagnostic accuracy of AI-enabled sinus rhythm (SR) electrocardiogram (ECG) interpretation for predicting paroxysmal or incident atrial fibrillation (AF). However, interethnic validations of these AI algorithms remain limited. We aimed to develop and comprehensively evaluate our AI model for predicting AF based on standard 12Dlead SR ECG images in a Korean population, and to validate its performance in Brazilian patient cohorts. MethodsWe developed a modified convolutional neural network model using a dataset comprising 811,542 ECGs from 121,600 patients at Seoul National University Bundang Hospital (2003-2020). Ninety percent of the patients were allocated to the training dataset, while the remaining 10% to the internal validation dataset. The model outputs a risk score (from 0 to 1) indicating the probability of concurrent paroxysmal or incident AF within 2 years, using standard-format 12Dlead SR ECG images. External validation was performed using the CODE 15% dataset, an open ECG dataset from the Telehealth Network of Minas Gerais, Brazil, by applying a 1:4 (AF:Non-AF) random sampling strategy. ResultsIn the internal validation, our AI model achieved an Area Under the Receiver Operating Characteristic Curve (AUROC) of 0.907 (95% CI: 0.897-0.916), with a sensitivity of 80.6% and a specificity of 85.0% for AF prediction. Subgroup analyses showed an AUROC of 0.874 (95% CI: 0.856-0.891) for patients in routine health checkups or outpatient settings, and 0.852 (95% CI: 0.824-0.880) for patients with "Normal ECG" interpretations. In the external interethnic validation with the CODE 15% dataset, the AI model exhibited an AUROC of 0.884 (95% CI: 0.869-0.900), which increased to 0.906 (95% CI: 0.893-0.919) when adjusted for age and sex. In the subset of patients with "Normal ECG" interpretations, the AUROC was 0.826 (95% CI: 0.769-0.883), increasing to 0.861 (95% CI: 0.814-0.908) after applying the same adjustments. ConclusionsOur AI-powered SR ECG interpretation model demonstrated excellent performance in predicting paroxysmal or incident AF, with valid performance in the Brazilian population as well. This suggests that the model has potential for broad application across different ethnic groups.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Atrial functional substrates for the prediction of atrial fibrillation recurrence after pulmonary vein isolation 96%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 95%
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 95%
Similar papers in this journal
- The Impact of Continuous Positive Airway Pressure Therapy on the Recurrence of Atrial Fibrillation in Patients with Obstructive Sleep Apnea after pulmonary vein isolation 96%
- Heart Rate n-Variability (HRnV) and Its Application to Risk Stratification of Chest Pain Patients in the Emergency Department 95%
- Diagnostic signature for Heart Failure with Preserved Ejection Fraction (HFpEF): A Machine Learning Approach Using Multi-Modality Electronic Health Record Data 94%
Similar papers in this journal
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 97%
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 96%
- Relationship of mild to moderate impairment of left ventricular ejection fraction with fatal ventricular arrhythmic events in cardiac sarcoidosis 95%
Similar papers in this journal
- International Evaluation Of An Artificial Intelligence-Powered Ecg Model Detecting Occlusion Myocardial Infarction 96%
- Automated Echocardiographic Detection of Mitral Valve Prolapse and Mitral Regurgitation with Video-based Artificial Intelligence Algorithms 95%
- Simple Models Versus Deep Learning in Detecting Low Ejection Fraction From The Electrocardiogram 94%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.