Back

Interethnic Validation of Artificial Intelligence for prediction of Atrial Fibrillation Using Sinus Rhythm Electrocardiogram

Lee, J. H.; Kim, J.; Choi, J.; Choi, Y. Y.; Oh, I.-Y.; Cho, Y.

2025-03-11 cardiovascular medicine
10.1101/2025.03.09.25323529 medRxiv
Show abstract

BackgroundPrevious research has demonstrated acceptable diagnostic accuracy of AI-enabled sinus rhythm (SR) electrocardiogram (ECG) interpretation for predicting paroxysmal or incident atrial fibrillation (AF). However, interethnic validations of these AI algorithms remain limited. We aimed to develop and comprehensively evaluate our AI model for predicting AF based on standard 12Dlead SR ECG images in a Korean population, and to validate its performance in Brazilian patient cohorts. MethodsWe developed a modified convolutional neural network model using a dataset comprising 811,542 ECGs from 121,600 patients at Seoul National University Bundang Hospital (2003-2020). Ninety percent of the patients were allocated to the training dataset, while the remaining 10% to the internal validation dataset. The model outputs a risk score (from 0 to 1) indicating the probability of concurrent paroxysmal or incident AF within 2 years, using standard-format 12Dlead SR ECG images. External validation was performed using the CODE 15% dataset, an open ECG dataset from the Telehealth Network of Minas Gerais, Brazil, by applying a 1:4 (AF:Non-AF) random sampling strategy. ResultsIn the internal validation, our AI model achieved an Area Under the Receiver Operating Characteristic Curve (AUROC) of 0.907 (95% CI: 0.897-0.916), with a sensitivity of 80.6% and a specificity of 85.0% for AF prediction. Subgroup analyses showed an AUROC of 0.874 (95% CI: 0.856-0.891) for patients in routine health checkups or outpatient settings, and 0.852 (95% CI: 0.824-0.880) for patients with "Normal ECG" interpretations. In the external interethnic validation with the CODE 15% dataset, the AI model exhibited an AUROC of 0.884 (95% CI: 0.869-0.900), which increased to 0.906 (95% CI: 0.893-0.919) when adjusted for age and sex. In the subset of patients with "Normal ECG" interpretations, the AUROC was 0.826 (95% CI: 0.769-0.883), increasing to 0.861 (95% CI: 0.814-0.908) after applying the same adjustments. ConclusionsOur AI-powered SR ECG interpretation model demonstrated excellent performance in predicting paroxysmal or incident AF, with valid performance in the Brazilian population as well. This suggests that the model has potential for broad application across different ethnic groups.

Published in Journal of Cardiovascular Medicine · not in our set (fewer than 10 published preprints to learn from) · training set

Matching journals

The top 7 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.