Challenging the classical view of CSF flow: measuring CSF net velocity in the human subarachnoid space with 7T MRI
Voort, E.;Plas, M.;Gosselink, M.;Zwanenburg, J.
Show abstract
Traditionally, cerebrospinal fluid (CSF) is believed to exit the brain via arachnoid villi, being absorbed into the superior sagittal sinus (SSS), with a net flow towards these exit sites driven by constant CSF turnover. However, measuring these velocities non-invasively in humans is challenging due to their slow nature and the presence of relatively large confounding factors such as physiological CSF pulsations (heartbeat and respiration) and head motion. This study presents a novel magnetic resonance imaging (MRI) method designed to measure the net velocity of CSF whilst accounting for confounding effects, which is called CSF displacement encoding with stimulated echoes (CSF-DENSE). By applying a similar model as used to study sea-level rise, different motion components of CSF were successfully disentangled. Simulations, along with phantom and in vivo experiments, demonstrate the ability of CSF-DENSE combined with time series analysis using unobserved components modeling to detect ultraslow velocities of approximately 1 μm/s, even in the presence of confounding motions that are an order of magnitude larger. If the major egress of CSF were via the SSS, the expected net velocity towards the SSS was estimated to be 4.22±0.14 µm/s, based on measured CSF net flow through the aqueduct into the subarachnoid space (SAS). However, no significant net velocity toward the SSS was observed (v = -0.18±0.15 µm/s, with positive velocity directed towards the SSS), thereby challenging the classical view of CSF outflow. These findings suggest the need to reconsider traditional models of CSF outflow pathways, with potential implications for understanding and treating neurological disorders.
Matching journals
The top 1 journal accounts for 50% of the predicted probability mass.
Similar papers in this journal
- Prospective Motion Correction and Automatic Segmentation of Penetrating Arteries in Phase Contrast MRI at 7 T 96%
- Multi-center benchmarking of cervical spinal cord RF coils for 7 T MRI: A traveling spines study 96%
- QSM Reconstruction Challenge 2.0: a realistic in silico head phantom for MRI data simulation and evaluation of susceptibility mapping procedures 96%
Similar papers in this journal
- Cerebrospinal Fluid Flow within Ventricles and Subarachnoid Space Evaluated by Velocity Selective Spin Labeling MRI 97%
- Decoding the microstructural properties of white matter using realistic models 96%
- Accuracy and precision in super-resolution MRI: Enabling spherical tensor diffusion encoding at ultra-high b-values and high resolution 96%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.