Estimating heart rate variability using facial video photoplethysmography: a pilot validation study
Pstras, L.; Okupnik, T.; Ponikowska, B.; Paleczny, B.
Show abstract
IntroductionVideo photoplethysmography (vPPG) employs a digital camera to detect blood pulsations in the skin vasculature, which can be used to estimate various physiological parameters. In this study, we investigate the accuracy and precision of two heart rate variability (HRV) indices estimated using a smartphone camera and the facial vPPG technology Shen.AI Vitals. MethodsThe study group included 35 healthy volunteers (17 females) with median age 25 years (range 20-42 years). The subjects were in a sitting position, keeping their heads relatively still. A smartphone mounted on a tripod was used to acquire 1-min video recordings of participants faces. In parallel, a 1-lead chest electrocardiogram (ECG) was recorded to obtain reference values of two analysed time-domain HRV indices: SDNN and lnRMSSD. ResultsFor SDNN, the mean absolute error (MAE) was 3.5 ms (11.0% in relative terms) and the root-mean-square error (RMSE) was 4.5 ms (15.7%). For lnRMSSD, the MAE was 0.24 (7.3%) and RMSE was 0.31 (9.9%). Correlations between the vPPG-based and ECG-based HRV values were strong, with the Pearson correlation coefficient of 0.98 for SDNN and 0.88 for lnRMSSD (P < 0.001 in both cases). ConclusionsIn a young, white population, the tested vPPG technology estimated HRV indices (SDNN and lnRMSSD) with acceptable accuracy in most subjects, with a slight systematic overestimation, especially for low values. The results should be confirmed in a larger study with greater diversity in age and skin tone.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Decrease of heart rate variability during exercise: an index of cardiorespiratory fitness 95%
- Estimating pulse wave velocity from the radial pressure wave using machine learning algorithms 95%
- Quantitative assessment of the relationship between behavioral and autonomic dynamics during propofol-induced unconsciousness 95%
Similar papers in this journal
- Comparison of wearable and clinical devices for acquisition of peripheral nervous system signals 97%
- Feasibility of Ultra-Short Term Analysis of Heart Rate and Systolic Arterial Pressure Variability at Rest and During Stress via Time-domain and Entropy-based Measures 96%
- In-Ear SpO2: A Tool for Wearable, Unobtrusive Monitoring of Hypoxaemia in COVID-19 94%
Similar papers in this journal
- Comparison of feature-based indices derived from photoplethysmogram recorded from different body locations during lower body negative pressure 97%
- An Open-Access Simultaneous Electrocardiogram and Phonocardiogram Database 96%
- High-Fidelity Measurement of Pulse Arrival Time in Critically Ill Children Using Standard Bedside Monitoring Equipment 93%
Similar papers in this journal
Similar papers in this journal
- Screening for Right Ventricular Dysfunction in the Emergency Department Using a Smartphone ECG Analysis Application: An External Validation Study with Acute Pulmonary Embolism Patients 93%
- Spectral features of heart rate variability in Williams syndrome during sleep 92%
- Artificial Intelligence in laryngeal endoscopy: Systematic Review and Meta-Analysis 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.