A method for efficient, rapid, and minimally invasive implantation of individual non-functional motes with penetrating subcellular-diameter carbon fiber electrodes into rat cortex

Letner, J. G.; Lam, J. L. W.; Copenhaver, M. G.; Barrow, M.; Patel, P. R.; Richie, J. M.; Lee, J.; Kim, H.-S.; Cai, D.; Weiland, J. D.; Phillips, J.; Blaauw, D.; Chestek, C. A.

2025-02-08 bioengineering
10.1101/2025.02.05.636655 bioRxiv
Show abstract

ObjectiveDistributed arrays of wireless neural interfacing chips with 1-2 channels each, known as "neural dust", could enhance brain machine interfaces (BMIs) by removing the wired connection through the scalp and increasing biocompatibility with their submillimeter size. Although several approaches for neural dust have emerged, a procedure for implanting them in batches that builds upon the safety and performance of currently used electrodes remains to be demonstrated. ApproachHere, we demonstrate the feasibility of implanting batches of wireless motes that rest on the cortical surface with carbon fiber electrodes of subcellular diameter (6.8-8.4 {micro}m) that penetrate to a target brain depth of 1 mm without insertion aids. To simulate their implantation, we assembled more than 230 mechanically equivalent motes and affixed them to insertion tools with polyethylene glycol (PEG), a quickly dissolvable and biocompatible material. Then, we implanted mote grids of multiple configurations into rat cortex in vivo and evaluated insertion success and their arrangement on the brain surface using photos and videos captured during their implantation. Main ResultsWhen placing motes onto the insertion device, we found that they aggregated in molten PEG such that the array pitch was only 5% wider than the dimensions of the mote bases themselves (240 x 240 {micro}m). Overall, we found that motes with this arrangement could be inserted into rat cortex with a high success rate, as 171/186 (92%) motes in 4x4 (N=4) and 5x5 (N=5) square grid configurations were successfully inserted using the insertion device alone. After implantation, measurements of how much motes tilted (22{+/-}9{degrees}, [X]{+/-}S) and had been displaced relative to their original positions were smaller than those measured for devices implanted inside the brain in the literature. SignificanceCollectively, these data establish the viability of safely implementing motes with ultrasmall electrodes and epicortically-situated chips for use in future BMIs.

Published in Frontiers in Neuroscience (predicted rank #22) · training set

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.