Measuring arterial tortuosity in the cerebrovascular system using Time-of-Flight MRI
Pan, Y.; Kahru, K.; Barinas-Mitchell, E.; Ibrahim, T. S.; Andreescu, C.; Karim, H.
Show abstract
The Circle of Willis (CW) is a critical cerebrovascular structure that supports collateral blood flow to maintain brain perfusion and compensate for eventual occlusions. Increased tortuosity of highrisk vessels within the CW has been implicated as a marker in the progression of cerebrovascular diseases especially in structures like the internal carotid artery (ICA). This is partly due to age-related plaque deposition or arterial stiffening. Producing reliable tortuosity measurements for vessels segmented from magnetic resonance (MR) time-of-flight (TOF) images requires precise curvature estimation, but existent methods struggle with noisy or sparse segmentation data. We introduce an open-source, end-to-end pipeline that uses unit-speed spline fitting for accurate curvature estimation, generating robust curvature-based tortuosity metrics for the ICA combined with an indicator of spline fit quality. We test this with theoretical data and apply this method to TOF data from 22 participants. We report that our metrics are able to capture tortuosity even under heightened noise constraints and discriminate different types of abnormal arterial coiling. We found that our ICA tortuosity measures correlate positively with age and ultrasound measured carotid artery intima media thickness. This ultimately has important translational implications for being able to reliably generate TOF tortuosity measures and estimate cerebrovascular disease burden. We provide open-source code in a GitHub repository.
Matching journals
The top 10 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Patient-specific compliant simulation framework informed by 4DMRI-extracted Pulse Wave Velocity: Application post-TEVAR 92%
- Foot perfusion. Insights from an anatomically detailed arterial network model 91%
- Automatic Generation of Personalised Skeletal Models of the Lower Limb from Three-Dimensional Bone Geometries 91%
Similar papers in this journal
- Selective ensemble methods for deep learning segmentation of major vessels in invasive coronary angiography 95%
- Necessity and Impact of Specialization of Large Foundation Model for Medical Segmentation Tasks 92%
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 92%
Similar papers in this journal
- Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: identifying reliable biomarkers such as ventricular relaxation rate 94%
- Reconstructing microvascular network skeletons from 3D images: what is the ground truth? 94%
- FFCM-MRF: An accurate and generalizable cerebrovascular segmentation pipeline for humans and rhesus monkeys based on TOF-MRA 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.