Long-term left atrial function after transcatheter device closure of patent foramen ovale in patients with cryptogenic stroke.
Gil-Jimenez, T.; Garcia Orta, R.; Villegas Rodriguez, I.; Caballero-Borrego, J.; Moreno Escobar, E.
Show abstract
AimsThe implantation of percutaneous atrial septal occluder (ASO) devices for patent foramen ovale (PFO) may affect left atrial (LA) function. Some studies have reported short- to mid-term impairment of this function, though it remains unclear whether this is a transient or permanent negative effect, nor if all patients are equally susceptible to these changes. Methods and resultsObservational, prospective study of consecutive patients with cryptogenic stroke (CS) undergoing percutaneous closure of PFO. Echocardiographic evaluation of evolving structural and functional parameters of the LA was carried out before procedure, inmediately after (within 24 hours), 6 and 18 months after device insertion. From March 2019 to October 2023, 170 patients with CS were enrolled, 82 eligible for PFO closure and 65 undergoing percutaneous closure. Baseline structural and functional parameters were within normal limits. At 6 months follow-up, there is a significant increase in LA volumes and a deterioration of reservoir and conduit functions measured by strain. There is a subsequent trend toward normalization, but baseline parameters are not reached by 18 months. ConclusionsPFO device closure negatively impacts on LA function, resulting in increased atrial volumes, worsening of left ventricular diastolic function, decreased reservoir and conduit function, and a compensatory increase in pump function. These changes are significant at 6 months, with partial improvement but without full normalization of parameters at 18 months follow-up.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Surgical strategy for atrial functional mitral regurgitation with atrial fibrillation 96%
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 96%
- Relationship of mild to moderate impairment of left ventricular ejection fraction with fatal ventricular arrhythmic events in cardiac sarcoidosis 95%
Similar papers in this journal
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 96%
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 96%
- Ticagrelor vs Clopidogrel: the Impact of Platelet Inhibition on Cerebrovascular Microembolic Events during TAVR 96%
Similar papers in this journal
Similar papers in this journal
- Autologous cardiac micrografts as support therapy to coronary artery bypass surgery 96%
- Electrocardiographic Abnormalities and Troponin Elevation in COVID-19 94%
- Improved Hemodynamic Performance and Reduced Paravalvular Regurgitation with the SAPIEN 3 Ultra RESILIA Valve: A Propensity-Matched Single-Center TAVR Study 94%
Similar papers in this journal
- Atrial Fibrillation Catheter Ablation among Cancer Patients: Utilization Trends and In-Hospital Outcomes 95%
- Risk and severity of COVID-19 and ABO blood group in transcatheter aortic valve patients 94%
- Screening for Right Ventricular Dysfunction in the Emergency Department Using a Smartphone ECG Analysis Application: An External Validation Study with Acute Pulmonary Embolism Patients 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.