Precise prostate contours: setting the bar and meticulously evaluating AI performance

Song, Y.; Dornisch, A. M.; Dess, R. T.; Margolis, D. J.; Weinberg, E.; Barrett, T.; Cornell, M.; Fan, R. E.; Harisinghani, M.; Kamran, S. C.; Lee, J. H.; Li, C. X.; Liss, M. A.; Rusu, M.; Santos, J.; Sonn, G. A.; Vidic, I.; Woolen, S. A.; Dale, A.; Seibert, T. M.

2024-10-22 radiology and imaging
10.1101/2024.10.21.24315771 medRxiv
Show abstract

IntroductionEvaluation of artificial intelligence (AI) algorithms for prostate segmentation is challenging because ground truth is lacking. We aimed to (1) create a reference standard dataset with precise prostate contours by expert consensus and (2) evaluate various AI tools against this standard. Materials and methodsWe obtained prostate MRI cases from six institutions from the Quantitative Prostate Imaging Consortium. A panel of four experts (two genitourinary radiologists, two prostate radiation oncologists) meticulously developed consensus prostate segmentations on axial T2-weighted series. We evaluated the performance of six AI tools (three commercially available, three academic) using Dice scores, distance from reference contour, and volume error. ResultsThe panel achieved consensus prostate segmentation on each slice of all 68 patient cases included in the reference dataset. We present two patient examples to serve as contouring guides. Depending on the AI tool, median Dice scores (across patients) ranged from 0.80 to 0.94 for whole prostate segmentation. For a typical (median) patient, AI tools had a mean error over the prostate surface ranging from 1.3 to 2.4 mm. They maximally deviated 3.0 to 9.4 mm outside the prostate and 3.0 to 8.5 mm inside the prostate for a typical patient. Error in prostate volume measurement for a typical patient ranged from 4.3% to 31.4%. DiscussionWe established an expert consensus benchmark for prostate segmentation. The best-performing AI tools have typical accuracy greater than that reported for radiation oncologists using CT scans (most common clinical approach for radiotherapy planning). Physician review remains essential to detect occasional major errors.

Matching journals

The top 5 journals account for 50% of the predicted probability mass.

1
Medical Physics
14 papers in training set
Top 0.1%
18.9%
2
International Journal of Radiation Oncology*Biology*Physics
25 papers in training set
Top 0.1%
13.2%
3
Scientific Reports
3612 papers in training set
Top 6%
8.1%
4
Clinical and Translational Radiation Oncology
10 papers in training set
Top 0.1%
6.9%
5
Biomedical Physics & Engineering Express
11 papers in training set
Top 0.1%
5.3%
50% of probability mass above
6
Journal of Medical Imaging
11 papers in training set
Top 0.1%
4.5%
7
BMC Cancer
67 papers in training set
Top 0.5%
4.1%
8
PLOS ONE
5266 papers in training set
Top 37%
3.3%
9
Frontiers in Oncology
103 papers in training set
Top 1%
2.7%
10
BMJ Open
601 papers in training set
Top 8%
2.5%
11
Scientific Data
209 papers in training set
Top 1%
2.4%
12
European Radiology
15 papers in training set
Top 0.3%
2.0%
13
Archives of Clinical and Biomedical Research
28 papers in training set
Top 0.4%
1.8%
14
JCO Clinical Cancer Informatics
22 papers in training set
Top 0.4%
1.7%
15
Nature Communications
5641 papers in training set
Top 45%
1.7%
16
Journal for ImmunoTherapy of Cancer
75 papers in training set
Top 1%
1.5%
17
Physics in Medicine & Biology
18 papers in training set
Top 0.2%
1.5%
18
Radiotherapy and Oncology
19 papers in training set
Top 0.3%
1.2%
19
Clinical Cancer Research
64 papers in training set
Top 1%
1.2%
20
eLife
5828 papers in training set
Top 64%
0.9%
21
Brain Structure and Function
93 papers in training set
Top 1%
0.9%
22
Biology Methods and Protocols
61 papers in training set
Top 3%
0.6%