Long-term clinical and patient reported outcomes of an enhanced monofocal intraocular lens
Latz, C.; Licht, A.; Ponto, K. A.; Menzel-Severing, J.; Pinero, D. P.; Mirshahi, A.
Show abstract
PurposeTo evaluate long-term clinical and patient-reported outcomes (PROMs) following the implantation of an enhanced monofocal intraocular lens (IOL). MethodsThis ambispective non-comparative single-centre study involved 41 patients (ages 48-84) who underwent bilateral cataract surgery with the Tecnis Eyhance IOL (model ICB00, Johnson & Johnson Vision). Distance and intermediate visual acuities, refraction, and PROMs were assessed 18 months or more after surgery. Spectacle independence was evaluated using the PRSIQ questionnaire, with patients self-reporting on visual quality, difficulties in performing specific tasks and perception of photic phenomena at distance and intermediate vision. ResultsAt 18 months or later, 100.0%, 73.2%, 100% and 79.5% of patients achieved a binocular uncorrected distance, uncorrected intermediate, corrected distance, and distance-corrected intermediate visual acuity of 0.20 logMAR or better, respectively. Less than 10% of patients reported photic phenomena. Mean visual quality scores were 1.68{+/-}0.72 for distance and 2.05{+/-}0.92 for intermediate vision (1=very good to 6=very poor). The dashboard was clearly visible while driving for 95.1% of patients, while 45.0% could perform screen work without glasses; an additional 40.0% could do so with enlarged fonts. Complete spectacle independence was reported by 87.8% for distance vision, and 53.7% for intermediate vision. At least moderately satisfied were 90.2% with distance vision, 87.8% with intermediate vision, and 51.2% with near vision. ConclusionsThe enhanced monofocal IOL ICB00 provides good long-term distance and intermediate visual quality, leading to considerable spectacle independence and patient satisfaction. Most patients required near vision correction.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- The learning curve of murine subretinal injection among clinically trained ophthalmic surgeons 96%
- Advanced Retinal Imaging and Ocular Parameters of the Rhesus Macaque Eye 95%
- Visual field evaluation using Zippy Adaptive Threshold Algorithm (ZATA) Standard and ZATA Fast in patients with glaucoma and healthy individuals 95%
Similar papers in this journal
- Risk Model for Intraoperative Complication during Cataract Surgery Based on Data from 900,000 Eyes – Previous Intravitreal Injection is a Risk Factor 97%
- Evaluation of the Nallasamy Formula: A Stacking Ensemble Machine Learning Method for Refraction Prediction in Cataract Surgery 97%
- AI-Powered Effective Lens Position Prediction Improves the Accuracy of Existing Lens Formulas 96%
Similar papers in this journal
- Factors predicting the visual outcome of intracorneal ring segment for keratoconus 98%
- Automated 360-degree goniophotography with the NIDEK Gonioscope GS-1 for glaucoma 97%
- The evaluation of a web‐based tool for measuring the uncorrected visual acuity and refractive error in keratoconus eyes: a prospective open‐label method comparison study 97%
Similar papers in this journal
- Iris Morphological and Biomechanical Factors Influencing Angle Closure During Pupil Dilation 95%
- Effect of eye globe and optic nerve morphologies on gaze-induced optic nerve head deformations 92%
- Inner limiting Membrane Peel Extends In vivo Calcium Imaging of Retinal Ganglion Cell Activity Beyond the Fovea in Non-Human Primate 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.