Examination of low-intensity focused ultrasound parameters for human neuromodulation
Ennasr, A.; Isaac, G.; Strohman, A.; Legon, W.
Show abstract
BackgroundLow-intensity focused ultrasound (LIFU) is a promising form of non-invasive neuromodulation characterized by a rich parameter space that includes intensity, duration, duty cycle and pulsing strategy. The effect and interaction of these parameters to affect human brain activity is poorly understood. A better understanding of how parameters interact is critical to advance LIFU as a potential therapeutic. Objective/HypothesisTo determine how different parameters, including intensity, duration, and duty cycle interact to produce neuromodulation effects in the human brain. Further, this study assesses the effect of pulsing versus continuous ultrasound. We hypothesize that higher duty cycles will confer excitation. Increasing intensity or duration will increase the magnitude of effect. Pulsing LIFU will not be more effective than continuous wave ultrasound. MethodsN = 18 healthy human volunteers underwent 20 different parameter combinations that included a fully parametrized set of two intensities (ISPPA: 6 & 24 W/cm2), five duty cycles (1, 10, 30, 50, 70%) and two durations (100, 500 msec) with a constant pulse repetition frequency of 1 kHz delivered concurrently with transcranial magnetic stimulation (TMS) to the primary motor cortex (M1). Four of these parameter combinations were also delivered continuously, matched on the number of cycles. Motor-evoked potential (MEP) amplitude was the primary outcome measure. All parameter combinations were collected time-locked to MEP generation. ResultsThere was no evidence of excitation from any parameter combination. 3 of the 24 parameter sets resulted in inhibition. The parameter set that resulted in the greatest inhibition ([~] 30%) was an intensity of 6W/cm2 with a duty cycle of 30% and a duration of 500 msec. A three-way ANOVA revealed an interaction of intensity and duty cycle. The analysis of continuous versus pulsed ultrasound revealed a 3-way interaction of intensity, pulsing, and the number of cycles such that under the 6W/cm2 condition higher cycles of pulsed ultrasound resulted in inhibition whereas lower number of cycles using continuous LIFU resulted in inhibition. ConclusionsLIFU to M1 in humans, in the range employed, either conferred inhibition or had no effect. Significant excitation was not observed. In general, lower intensity looks to be more efficacious for inhibition that depends on duration. Finally, pulsed ultrasound looks to be more effective for inhibition as compared to continuous wave after controlling for total energy delivered.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
Similar papers in this journal
- Non-invasive stimulation with Temporal Interference: Optimization of the electric field deep in the brain with the use of a genetic algorithm 94%
- Optimized Monophasic Pulses with Equivalent Electric Field for Rapid-Rate Transcranial Magnetic Stimulation 94%
- TRPV1-mediated sonogenetic neuromodulation of motor cortex in freely moving mice 94%
Similar papers in this journal
- Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter? 95%
- Cerebellar transcranial direct current stimulation disrupts neuroplasticity of intracortical motor circuits. 95%
- Vibrotactile auricular vagus nerve stimulation alters limbic system connectivity in humans: A pilot study 95%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.