Comparison of test-retest reproducibility of DESPOT and 3D-QALAS for water T1 and T2 mapping
Simegn, G. L.; Gagoski, B.; Song, Y.; Dean, D. C.; Hupfelda, K. E.; Murali-Manohara, S.; Davies-Jenkinsa, C. W.; Simicic, D.; Wisnowskij, J.; Yedavallia, V.; Gudmundson, A. T.; Zollner, H. J.; Oeltzschner, G.; Edden, R. A. E.
Show abstract
PurposeRelaxometry, specifically T1 and T2 mapping, has become an essential technique for assessing the properties of biological tissues related to various physiological and pathological conditions. Many techniques are being used to estimate T1 and T2 relaxation times, ranging from the traditional inversion or saturation recovery and spin-echo sequences to more advanced methods. Choosing the appropriate method for a specific application is critical since the precision and accuracy of T1 and T2 measurements are influenced by a variety of factors including the pulse sequence and its parameters, the inherent properties of the tissue being examined, the MRI hardware, and the image reconstruction. The aim of this study is to evaluate and compare the test-retest reproducibility of two advanced MRI relaxometry techniques (Driven Equilibrium Single Pulse Observation of T1 and T2, DESPOT, and 3D Quantification using an interleaved Look-Locker acquisition Sequence with a T2 preparation pulse, QALAS), for T1 and T2 mapping in a healthy volunteer cohort. Methods10 healthy volunteers underwent brain MRI at 1.3 mm3 isotropic resolution, acquiring DESPOT and QALAS data ([~]11.8 and [~]5 minutes duration, including field maps, respectively), test-retest with subject repositioning, on a 3.0 Tesla Philips Ingenia Elition scanner. To reconstruct the T1 and T2 maps, we used an equation-based algorithm for DESPOT and a dictionary-based algorithm that incorporates inversion efficiency and B1-field inhomogeneity for QALAS. The test-retest reproducibility was assessed using the coefficient of variation (CoV), intraclass correlation coefficient (ICC) and Bland-Altman plots. ResultsOur results indicate that both the DESPOT and QALAS techniques demonstrate good levels of test-retest reproducibility for T1 and T2 mapping across the brain. Higher whole-brain voxel-to-voxel ICCs are observed in QALAS for T1 (0.84 {+/-} 0.039) and in DESPOT for T2 (0.897 {+/-} 0.029). The Bland-Altman plots show smaller bias and variability of T1 estimates for QALAS (mean of -0.02 s, and upper and lower limits of -0.14 and 0.11 s, 95% CI) than for DESPOT (mean of -0.02 s, and limits of -0.31 and 0.27 s). QALAS also showed less variability (mean 1.08 ms, limits -1.88 to 4.04 ms) for T2 compared to DESPOT (mean of 2.56 ms, and limits -17.29 to 22.41 ms). The within-subject CoVs for QALAS range from 0.6% (T2 in CSF) to 5.8% (T2 in GM), while for DESPOT they range from 2.1% (T2 in CSF) to 6.7% (T2 in GM). The between-subject CoVs for QALAS range from 2.5% (T2 in GM) to 12% (T2 in CSF), and for DESPOT they range from 3.7% (T2 in WM) to 9.3% (T2 in CSF). ConclusionOverall, QALAS demonstrated better reproducibility for T1 and T2 measurements than DESPOT, in addition to reduced acquisition time.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Comparison of BOLD and CBV using 3D EPI and 3D GRASE for cortical layer fMRI at 7T. 97%
- Myelin water imaging depends on white matter fiber orientation in the human brain 97%
- Combining Navigator and Optical Prospective Motion Correction for High-Quality 500 μm Resolution Quantitative Multi-Parameter Mapping at 7T 97%
Similar papers in this journal
- Cerebrospinal Fluid Flow within Ventricles and Subarachnoid Space Evaluated by Velocity Selective Spin Labeling MRI 96%
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions 96%
- Multi-centre, multi-vendor reproducibility of 7T QSM and R2* in the human brain: results from the UK7T study 96%
Similar papers in this journal
- Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions 97%
- Tailored Magnetic Resonance Fingerprinting 96%
- Simulated Diagnostic Performance of Ultra-Low-Field MRI: Harnessing Open-Access Datasets to Evaluate Novel Devices 95%
Similar papers in this journal
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.