EEG source imaging technique to investigate sleep oscillations for simultaneous EEG-fMRI
Uji, M.; Jegou, A.; Cross, N. E.; Pomares, F. B.; Perrault, A. A.; Nguyen, A.; Aydin, U.; Lee, K.; Abdallah, C.; Frauscher, B.; Lina, J.-M.; Dang-Vu, T. T.; Grova, C.
Show abstract
Simultaneous recording of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) is a widely used non-invasive neuroimaging technique in sleep studies. However, EEG data are strongly influenced by two types of MRI-related artefacts: gradient artefacts (GA) and ballistocardiogram artefacts (BCG). If artefacts correction is suboptimal, the BCG obscures the EEG signals below 20Hz and could make it difficult to investigate sleep oscillations, especially sleep spindles, sleep specific oscillations occurring within 11-16Hz frequency band. We previously demonstrated the utility of beamforming spatial filtering in correcting MRI-related artefacts on EEG. Here, we investigated the use of beamforming spatial filtering for improving the detection of EEG oscillations during sleep, in particular, 1) to accurately estimate single-event spindle EEG power changes, and 2) to demonstrate the potential improvement of fMRI general linear model (GLM) analysis when involving such additional EEG information. We analysed EEG-fMRI data acquired during a recovery nap after sleep deprivation in 20 young healthy participants (12 females, 8 males, age = 21.3 {+/-} 2.5 years). Based on spindle events (onset and duration) detected by trained sleep scorers on BCG corrected EEG signals through a conventional average artefact subtraction (AAS) method, we compared four different EEG processing steps: non-BCG corrected; AAS BCG corrected; beamforming BCG corrected; beamforming+AAS BCG corrected. These processing steps consist of non-BCG corrected and AAS BCG corrected considered either at the sensor level or at the source-level (after beamformer localization) to evaluate the impact of the BCG artefact on the detection of spindle activity. Then we further investigated four different fMRI GLM approaches using 1) the spindle onset and duration (GLM1), 2) spindle onset, duration, and parametric modulation of single-spindle power change from the Cz electrode of the AAS BCG corrected data (GLM2), 3) spindle onset, duration, and parametric modulation of single-spindle power change from the beamforming+AAS BCG corrected (GLM3) and 4) spindle onset, duration, and parametric modulation of single-spindle power change from the beamforming BCG corrected data (GLM4). We found that the beamforming approach did not only attenuate the BCG artefacts, but also recovered sleep spindle activity occurring during NREM sleep. Furthermore, this beamforming approach allowed us to accurately estimate single-event power change of each spindle in the source space when compared to the channel level analysis, and therefore to further improve the specificity of fMRI GLM analysis, better localizing the recruited brain regions during spindles. Our findings show the benefit of applying beamforming source imaging technique to EEG-fMRI acquired during sleep. We demonstrate that this approach would be beneficial especially for long EEG-fMRI data acquisitions (i.e., sleep, resting-state), when the BCG correction becomes problematic due to inherent dynamic changes of heart rates. Our findings extend previous work regarding the application of the source imaging to the sleep EEG-fMRI. Combining with this advanced methodology and analysis, sleep EEG-fMRI will help us better understand the functional roles of human sleep.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Data-driven beamforming techniques to attenuate ballistocardiogram (BCG) artefacts in EEG-fMRI without detecting cardiac pulses in electrocardiography (ECG) recordings 97%
- RELAX-Jr: An Automated Pre-Processing Pipeline for Developmental EEG Recordings 95%
- Estimating functional EEG sources using topographical templates 95%
Similar papers in this journal
- Spatial (Mis)match Between EEG and fMRI Signal Patterns Revealed by Spatio-Spectral Source-Space EEG Decomposition 96%
- Demonstrating the need for long inter-stimulus intervals when studying the post-movement beta rebound following a simple button press 95%
- Modulation of gamma spectral amplitude and connectivity during reaching predicts peak velocity and movement duration 94%
Similar papers in this journal
- Optimizing EEG source reconstruction with concurrent fMRI-derived spatial priors 95%
- Qualitative and Quantitative Comparative Analysis of Common Normal Variants and Physiological Artifacts in MEG and EEG 94%
- Modeling the hemodynamic response function using EEG-fMRI data during eyes-open resting-state conditions and motor task execution 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.