Methodological approaches to derive the heartbeat-evoked potential: pastpractices and future recommendations
Virjee, R.-I.; Kandasamy, R.; Garfinkel, S.; Carmichael, D.; Yogarajah, M.
Show abstract
The heartbeat-evoked potential (HEP) is an implicit, electrophysiological marker of cortical heartbeat processing and interoception, with increasing clinical relevance. However, on the scalp, HEP are low-amplitude signals mixed with cardiac field artefacts (CFA), requiring signal processing pipelines to separate HEP from CFA. This review evaluates current analytical approaches, addresses methodological gaps in HEP pipelines, and examines the impact of key parameter choices. HEP processing methods/parameters used in EEG (N=101) and MEG (N=10) studies were investigated, focusing on the effects of HEP window, electrodes, filters, independent component analysis (ICA) and artefact subspace reconstruction (ASR), on HEP extraction, using Temple Universitys normal scalp EEG data. EEG and MEG studies revealed clear inconsistencies in HEP parameter use and reporting. ASR-20 (ASR threshold for artifact identification) performed comparably to ICA for artefact removal, supporting its potential real-time EEG applicability. Epoch rejection, a HEP quality metric, appeared equivalent between ICA and ASR-20 after artefact removal. Linear Mixed Model analysis identified significant effects of RR interval, maximum epoch amplitude, HEP window and baseline correction start time on measured HEP amplitude. Publications should report critical values for reliable HEP extraction, emphasising the need for standardised methods to enhance study comparability and reproducibility.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- A comparison between power spectral density and network metrics: an EEG study 96%
- Subject, session and task effects on power, connectivity and network centrality: a source-based EEG study 96%
- A Transfer Entropy-based methodology to analyze information flow under eyes-open and eyes-closed conditions with a clinical perspective 96%
Similar papers in this journal
- Wavelet Phase Coherence of Ictal Scalp EEG-Extracted Muscle Activity (SMA) as a Biomarker for Sudden Unexpected Death in Epilepsy (SUDEP) 95%
- Stimulus-induced narrow-band gamma oscillations in humans can be recorded using open-hardware low-cost EEG amplifier 95%
- Application of machine learning and complex network measures to an EEG dataset from ayahuasca experiments 95%
Similar papers in this journal
- Introducing RELAX (the Reduction of Electroencephalographic Artifacts): A fully automated pre-processing pipeline for cleaning EEG data - Part 1: Algorithm and Application to Oscillations 95%
- Fast oscillations >40Hz localize the epileptogenic zone: an electrical source imaging study using high-density electroencephalography 94%
- Dynamic Training of a Novelty Classifier Algorithm for Real-Time Early Seizure Onset Detection 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.