Deep Learning Phenotyping of Tricuspid Regurgitation for Automated High Throughput Assessment of Transthoracic Echocardiography
Vrudhula, A.; Vukadinovic, M.; Haeffele, C.; Kwan, A. C.; Berman, D. S.; Liang, D. H.; Siegel, R.; Cheng, S.; Ouyang, D.
Show abstract
Background and AimsDiagnosis of tricuspid regurgitation (TR) requires careful expert evaluation. This study developed an automated deep learning pipeline for assessing TR from transthoracic echocardiography. MethodsAn automated deep learning workflow was developed using 47,312 studies (2,079,898 videos) from Cedars-Sinai Medical Center (CSMC) between 2011 and 2021. The pipeline was tested on a temporally distinct test set of 2,462 studies (108,138 videos) obtained in 2022 at CSMC and a geographically distinct cohort of 5,549 studies (278,377 videos) from Stanford Healthcare (SHC). ResultsIn the CSMC test dataset, the view classifier demonstrated an AUC of 1.000 (0.999 - 1.000) and identified at least one A4C video with colour Doppler across the tricuspid valve in 2,410 of 2,462 studies with a sensitivity of 0.975 (0.968-0.982) and a specificity of 1.000 (1.00-1.000). In the CSMC test cohort, moderate-or-severe TR was detected with an AUC of 0.928 (0.913 - 0.943) and severe TR was detected with an AUC of 0.956 (0.940 - 0.969). In the SHC cohort, the view classifier correctly identified at least one TR colour Doppler video in 5,268 of the 5,549 studies, resulting in an AUC of 0.999 (0.998 - 0.999), a sensitivity of 0.949 (0.944 - 0.955) and specificity of 0.999 (0.999 - 0.999). The AI model detected moderate-or-severe TR with an AUC of 0.951 (0.938 - 0.962) and severe TR with an AUC of 0.980 (0.966 - 0.988). ConclusionsWe developed an automated pipeline to identify clinically significant TR with excellent performance. This approach carries potential for automated TR detection and stratification for surveillance and screening. Structured Graphical Abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=146 SRC="FIGDIR/small/24309332v1_ufig1.gif" ALT="Figure 1"> View larger version (45K): org.highwire.dtl.DTLVardef@1fc051forg.highwire.dtl.DTLVardef@b46460org.highwire.dtl.DTLVardef@129f39borg.highwire.dtl.DTLVardef@1384ef1_HPS_FORMAT_FIGEXP M_FIG Computer Vision Based Tricuspid Regurgitation (TR) Detection: An automated deep learning pipeline was trained to stratify tricuspid regurgitation severity using large-scale data in the form of A4C TTE videos with colour Doppler across the tricuspid valve. The pipeline generalized across two geographically distinct test sets from CSMC and SHC, demonstrating the pipelines ability to detect clinically significant TR using single-view TTE videos with Doppler information. These results open the door to potential TR point-of-care screening. C_FIG Key QuestionCan an automated deep learning model assess tricuspid regurgitation severity from echocardiography? Key FindingWe developed and validated an automated tricuspid regurgitation detection algorithm pipeline across two healthcare systems with high volume echocardiography labs. The algorithm correctly identifies apical-4-chamber view videos with colour Doppler across the tricuspid valve and grades clinically significant TR with strong agreement to expert clinical readers. Take Home messageA deep learning pipeline could automate TR screening, facilitating reproducible accurate assessment of TR severity, allowing rapid triage or re-review and expand access in low-resource or primary care settings.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Automated Echocardiographic Detection of Mitral Valve Prolapse and Mitral Regurgitation with Video-based Artificial Intelligence Algorithms 95%
- Simple Models Versus Deep Learning in Detecting Low Ejection Fraction From The Electrocardiogram 95%
- Development and Multinational Validation of an Ensemble Deep Learning Algorithm for Detecting and Predicting Structural Heart Disease Using Noisy Single-lead Electrocardiograms 94%
Similar papers in this journal
- High Throughput Deep Learning Detection of Mitral Regurgitation 99%
- Transcatheter or Surgical Aortic Valve Replacement in Patients with Severe Aortic Stenosis and Small Aortic Annulus: A Randomized Clinical Trial 93%
- Comparison of Long-term Outcomes of Early Surgery Versus Conventional Treatment for Asymptomatic Severe Mitral Regurgitation: A Propensity Analysis 93%
Similar papers in this journal
- A Multicenter Evaluation of the Impact of Procedural and Pharmacological Interventions on Deep Learning-based Electrocardiographic Markers of Hypertrophic Cardiomyopathy 95%
- Natural Language Processing for the Ascertainment and Phenotyping of Left Ventricular Hypertrophy and Hypertrophic Cardiomyopathy on Echocardiogram Reports 94%
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 94%
Similar papers in this journal
- Right Heart Remodeling After Pulmonary Valve Replacement in Patients with Pulmonary Atresia or Critical Stenosis with Intact Ventricular Septum 94%
- The HeartMagic prospective observational study protocol - characterizing subtypes of heart failure with preserved ejection fraction 94%
- Prognostic Value of Patient-Reported Outcomes in Predicting Long-term Mortality after Transcatheter Aortic Valve Replacement (TAVR) 93%
Similar papers in this journal
- Algorithm for Predicting Valvular Heart Disease from Heart Sounds in an Unselected Cohort 96%
- Fairness in Cardiac Magnetic Resonance Imaging: Assessing sex and racial bias in deep learning-based segmentation 94%
- Improved Hemodynamic Performance and Reduced Paravalvular Regurgitation with the SAPIEN 3 Ultra RESILIA Valve: A Propensity-Matched Single-Center TAVR Study 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.