Head-to-head comparison of diagnostic accuracy of TB screening tests: Chest X-ray, Xpert TB host response, and C-reactive protein
Crowder, R.; Thangakunam, B.; Andama, A.; Christopher, D. J.; Dalay, V.; Dube-Nwamba, W.; Kik, S. V.; Van Nguyen, D.; Viet Nhung, N.; Phillips, P. P.; Ruhwald, M.; Theron, G.; Worodria, W.; Yu, C.; Nahid, P.; Cattamanchi, A.; Gupta-Wright, A.; Denkinger, C. M.
Show abstract
BackgroundAccessible, accurate screening tests are necessary to advance tuberculosis (TB) case finding and early detection in high-burden countries. We compared the diagnostic accuracy of available TB triage tests. MethodsWe prospectively screened consecutive adults with [≥]2 weeks of cough presenting to primary health centers in the Philippines, Vietnam, South Africa, Uganda, and India. All participants received the index tests: chest-X-ray (CXR), venous or capillary Cepheid Xpert TB Host Response (HR) testing, and point-of-care C-reactive protein (CRP) testing (Boditech iChroma II). CXR images were processed using computer-aided detection (CAD) algorithms. We assessed diagnostic accuracy against a microbiologic reference standard (sputum Xpert Ultra, culture). Optimal cut-points were chosen to achieve sensitivity [≥]90% and maximize specificity. Two-test screening algorithms were considered, using two approaches: 1) sequential negative serial screening in which the second screening test is conducted only if the first is negative and positive is defined as positive on either test and 2) sequential positive serial screening, in which the second screening test is conducted only if the first is positive and positive is defined as positive on both tests. ResultsBetween July 2021 and August 2022, 1,392 participants with presumptive TB had valid results on index tests and the reference standard, and 303 (22%) had confirmed TB. In head-to-head comparisons, CAD4TB v7 showed the highest specificity when using a cut-point that achieves 90% sensitivity (70.3% vs. 65.1% for Xpert HR, difference 95% CI 1.6 to 8.9; 49.7% for CRP, difference 95% CI 17.0 to 24.3). Among the possible two-test screening algorithms, three met WHO target product profile (TPP) minimum accuracy thresholds and had higher accuracy than any test alone. At 90% sensitivity, the specificity was 79.6% for Xpert HR-CAD4TB [sequential negative], 75.9% for CRP-CAD4TB [sequential negative], and 73.7% for Xpert HR-CAD4TB [sequential positive]. ConclusionsCAD4TB achieves TPP targets and outperforms Xpert HR and CRP. Combining screening tests further increased accuracy. Cost and feasibility of two-test screening algorithms should be explored. RegistrationNCT04923958
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Complementary non-sputum diagnostic testing using oral swabs and urine LAM testing for TB in people with HIV 97%
- Accuracy of tongue swab testing using Xpert MTB-RIF Ultra for tuberculosis diagnosis 96%
- Host blood protein biomarkers to screen for Tuberculosis disease: a systematic review and meta-analysis 96%
Similar papers in this journal
- Programmatic diagnostic accuracy and clinical utility of Xpert MTB/XDR in patients with rifampicin-resistant tuberculosis in Georgia 97%
- C-reactive protein for pulmonary tuberculosis screening and treatment response monitoring in children 96%
- Potential Utility of C-reactive Protein for Tuberculosis Risk Stratification among Patients with Non-Meningitic Symptoms at HIV Diagnosis in Low- and Middle-Income Countries 96%
Similar papers in this journal
- Accuracy of digital chest x-ray analysis with artificial intelligence software as a triage and screening tool in hospitalized patients being evaluated for tuberculosis in Lima, Peru 98%
- Diagnostic accuracy study of the multiplex Truenat MTB Ultima/COVID-19 assay for simultaneous detection of Tuberculosis and SARS-CoV2 (COVID-19) 97%
- Diagnostic accuracy of three computer-aided detection systems for detecting pulmonary tuberculosis on chest radiography when used for screening: analysis of an international, multicenter migrants screening study 96%
Similar papers in this journal
- Stool processing methods for Xpert Ultra testing in childhood tuberculosis: A prospective, multi-country accuracy study 96%
- New manual qPCR assay validated on tongue swabs collected and processed in Uganda shows sensitivity that rivals sputum-based molecular TB diagnostics 96%
- Sputum and tongue swab molecular testing for the in-home diagnosis of tuberculosis in unselected household contacts: a cost and cost-effectiveness analysis 96%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.