BackgroundSuture anchor failures can lead to revision surgeries which are costly and burdensome for patients. The durability of musculoskeletal reconstructions is therefore partly affected by the design of the suture anchors. PurposeThe purpose of the study was to quantify the strength of different suture anchors whose sizes are suitable for attaching artificial Achilles and tibialis cranialis tendons in a rabbit model, as well as determine the effect of cyclic loading on the anchoring strength. MethodFour anchors (two with embedded eyelet and two with raised eyelet, n=5 per group) were tested with cyclical loading (1000 cycles and 4.5 mm/sec) and without cycling, to inform the failure loads and mode of failure of the suture anchors. An eyebolt screw with smooth eyelet was used as a control for the test groups. ResultsAll samples in all groups completed 1000 cycles and failed via suture breakage in both test conditions. All anchors had failure loads exceeding the peak Achilles tendon force in rabbits during hopping gait. The data analysis showed an effect of anchor type on the maximum tensile force at failure (Fmax) in all suture categories but not an effect of loading condition. Also, the Anika anchor had a significantly less adverse effect on suture strength compared to Arthrex anchor (p=0.015), IMEX anchor (p=0.004) and Jorvet anchor (p<0.001). We observed a greater percentage of failure at the mid-section for the anchors with the raised eyelets compared to the anchors with embedded eyelets, which all failed at the knot. ConclusionAnchors with embedded eyelets had clinically preferred mode of failure with less adverse effects on suture and, may be more reliable than anchors with raised eyelets for attaching artificial Achilles and tibialis cranialis tendons in rabbits.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Cyclic Loading Induces Anabolic and Catabolic Gene Expression in ACLs in a Load-Dependent and Sex-Specific Manner 94%
- Measuring Tibial Forces is More Useful than Varus-Valgus Laxities for Identifying and Correcting Overstuffing in Kinematically Aligned Total Knee Arthroplasty 94%
- Acoustic Prediction and Biomechanical Validation of Primary Stability in Uncemented Short-Stem Hip Prostheses: An In Vitro Study 93%
Similar papers in this journal
- Tissue-specific changes in size and shape of the ligaments and tendons of the porcine knee during post-natal growth 94%
- Biomechanical effects of adding an articulating toe joint to a passive foot prosthesis for incline and decline walking 93%
- Diminishing effects of mechanical loading over time during rat Achilles tendon healing 93%
Similar papers in this journal
- Attaching artificial Achilles and tibialis cranialis tendons to bone using suture anchors in a rabbit model: assessment of outcomes 99%
- Viscoelastic characteristics of the canine cranial cruciate ligament complex at slow strain rates 96%
- Geometric variation of the human tibia-fibula: A public dataset of tibia-fibula surface meshes and statistical shape model 92%
Similar papers in this journal
- An equine tendon model for studying intra-tendinous shear in tendons that have more than one muscle contribution 96%
- Intermittent Cyclic Stretch of Engineered Ligaments Drives Hierarchical Collagen Fiber Maturation in a Dose- and Organizational-Dependent Manner 93%
- Elastase treatment of tendon specifically impacts the mechanical properties of the interfascicular matrix 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.