Back

Frequency-dependence in multidimensional diffusion-relaxation correlation MRI of the brain: overfitting or meaningful parameter?

Yon, M.; Narvaez, O.; Martin, J.; Jiang, H.; Bernin, D.; Forssell-Aronsson, E.; Laun, F.; Sierra, A.; Topgaard, D.

2024-04-30 biophysics
10.1101/2024.04.29.591586 bioRxiv
Show abstract

Time- or frequency-dependent ("restricted") diffusion potentially provides useful information about cellular-scale structures in the brain but is challenging to interpret because of the intravoxel tissue heterogeneity. Frequency-dependence was recently incorporated in a multidimensional diffusion-relaxation correlation MRI framework relying on tensor-valued diffusion encoding at multiple frequencies, as well as variable echo and repetition times, to give model-free characterization of intravoxel heterogeneity by Monte Carlo data inversion into nonparametric distributions of frequency-dependent diffusion tensors and nuclear relaxation rates. While microimaging equipment with high-amplitude magnetic field gradients allows exploration of frequencies from tens to hundreds of Hz, clinical scanners with more moderate gradient capabilities are limited to a narrow frequency range, which may be insufficient to observe effects of restricted diffusion for brain tissues. We here investigate the effects of including or omitting frequency-dependence in the data inversion from isotropic and anisotropic liquids, excised tumor tissue, ex vivo mouse brain, and in vivo human brain. For microimaging measurements covering a wide frequency range, from 35 to 320 Hz at b-values over 4{middle dot}109 sm-2, the inclusion of frequency-dependence drastically reduces the fit residuals and avoids bias in the diffusion metrics for tumor and brain voxels with micrometer-scale structures. Conversely, for the case of in vivo human brain investigated in the narrow frequency range from 5 to 11 Hz at b = 3{middle dot}109 sm-2, analyses with and without inclusion of frequency-dependence yield similar fit residuals and diffusion metrics for all voxels. These results indicate that frequency-dependent inversion may be generally applied to diffusion-relaxation correlation MRI data with and without observable effects of restricted diffusion.

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.