Mirror-assisted light-sheet microscopy: a simple upgrade to enable bi-directional sample excitation
Zylbertal, A.; Bianco, I. H.
Show abstract
SignificanceLight-sheet microscopy is a powerful imaging technique that achieves optical sectioning via selective illumination of individual sample planes. However, when the sample contains opaque or scattering tissue, the incident light-sheet may not be able to uniformly excite the entire sample. For example, in the context of larval zebrafish whole-brain imaging, occlusion by the eyes prevents access to a significant portion of the brain during common implementations using unidirectional illumination. AimWe introduce mirror-assisted light-sheet microscopy (mLSM), a simple inexpensive method that can be implemented on existing digitally scanned light-sheet setups by adding a single optical element - a mirrored micro-prism. The prism is placed near the sample to generate a second excitation path for accessing previously obstructed regions. ApproachScanning the laser beam onto the mirror generates a second, reflected illumination path that circumvents the occlusion. Online tuning of the scanning and laser power waveforms enables near uniform sample excitation with dual illumination. ResultsmLSM produces cellular-resolution images of zebrafish brain regions inaccessible to unidirectional illumination. Imaging quality in regions illuminated by the direct or reflected sheet is adjustable by translating the excitation objective. The prism does not interfere with visually guided behaviour. ConclusionsmLSM presents an easy to implement, cost-effective way to upgrade an existing light-sheet system to obtain more imaging data from a biological sample.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Widefield in vivo imaging system with two fluorescence and two reflectance channels, a single sCMOS detector, and shielded illumination 96%
- Subcellular resolution 3D light field imaging with genetically encoded voltage indicators 94%
- Aberration correction in STED microscopy to increase imaging depth in living brain tissue 94%
Similar papers in this journal
Similar papers in this journal
- An evaluation of multi-excitation-wavelength standing-wave fluorescence microscopy (TartanSW) to improve sampling density in studies of the cell membrane and cytoskeleton 95%
- Ultra-thin fluorocarbon foils optimize multiscale imaging of three-dimensional native and optically cleared specimens 94%
- 96 Eyes: Parallel Fourier Ptychographic Microscopy for high throughput screening 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.