Model-based frequency-and-phase correction of 1H MRS data with 2D linear-combination modeling.
Simicic, D.; Zöllner, H. J.; Davies-Jenkins, C. W.; Hupfeld, K. E.; Edden, R. A. E.; Oeltzschner, G.
Show abstract
PurposeRetrospective frequency-and-phase correction (FPC) methods attempt to remove frequency- and-phase variations between transients to improve the quality of the averaged MR spectrum. However, traditional FPC methods like spectral registration struggle at low SNR. Here, we propose a method that directly integrates FPC into a two-dimensional linear-combination model (2D-LCM) of individual transients ( model-based FPC). We investigated how model-based FPC performs compared to the traditional approach, i.e., spectral registration followed by 1D-LCM in estimating frequency-and-phase drifts and, consequentially, metabolite level estimates. MethodsWe created synthetic in-vivo-like 64-transient short-TE sLASER datasets with 100 noise realizations at 5 SNR levels and added randomly sampled frequency and phase variations. We then used this synthetic dataset to compare the performance of 2D-LCM with the traditional approach (spectral registration, averaging, then 1D-LCM). Outcome measures were the frequency/phase/amplitude errors, the standard deviation of those ground-truth errors, and amplitude Cramer Rao Lower Bounds (CRLBs). We further tested the proposed method on publicly available in-vivo short-TE PRESS data. Results2D-LCM estimates (and accounts for) frequency-and-phase variations directly from uncorrected data with equivalent or better fidelity than the conventional approach. Furthermore, 2D-LCM metabolite amplitude estimates were at least as accurate, precise, and certain as the conventionally derived estimates. 2D-LCM estimation of frequency and phase correction and amplitudes performed substantially better at low-to-very-low SNR. ConclusionModel-based FPC with 2D linear-combination modeling is feasible and has great potential to improve metabolite level estimation for conventional and dynamic MRS data, especially for low-SNR conditions, e.g., long TEs or strong diffusion weighting.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI 95%
- Mapping of Glutamate Metabolism using 1H FID-MRSI after oral Administration of Glc at 9.4 T 95%
- Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T 94%
Similar papers in this journal
- Diffusion MRS tracks distinct trajectories of neuronal development in the cerebellum and thalamus of rat neonates. 96%
- Magnetic Resonance measurements of cellular and sub-cellular membrane structures in live and fixed neural tissue 92%
- Perception affects the brain's metabolic response to sensory stimulation 92%