Longevity of Implantable Silicon-ICs for Emerging Neural Applications: Evaluation of Bare Die and PDMS-Coated ICs After Accelerated Aging and Implantation Studies
Nanbakhsh, K.; Idil, A. S.; Lamont, C.; Ducso, C.; Akgun, O. C.; Horvath, D.; Toth, K.; Ulbert, I.; Mazza, F.; Constandinou, T.; Serdijn, W. A.; Vanhoestenberghe, A.; Donaldson, N.; Giagka, V.
Show abstract
Silicon integrated circuits (ICs) are central to the next-generation miniature active neural implants, whether packaged in soft polymers for flexible bioelectronics or implanted as bare die for neural probes. These emerging applications bring the IC closer to the corrosive body environment, raising reliability concerns, particularly for long-term clinical use. Here, we evaluated the long-term electrical and material stability of silicon-ICs from two foundries, after one-year accelerated in vitro and in vivo animal studies. The ICs featured various custom-designed test structures and were partially PDMS coated, creating two regions on each chip, uncoated "bare die" and "PDMS-coated". During the accelerated in vitro study, ICs were electrically biased and periodically monitored. Results demonstrated stable electrical performance for at least a year, suggesting that bare die ICs can function in the body for months. Despite electrical stability, material analysis revealed chemical and electrically driven degradation of the IC passivation in the bare die regions. In contrast, PDMS-coated regions revealed no such degradation, making PDMS a highly suitable encapsulant for ICs intended for years-long implantation. Based on the new insights, guidelines are proposed that may enhance the longevity of implantable ICs, significantly broadening their applications in the biomedical field.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Fabrication and Modeling of Recessed Traces for Silicon-Based Neural Microelectrodes 95%
- Intracortical probe arrays with silicon backbone and microelectrodes on thin polyimide wings enable long-term stable recordings in vivo 93%
- Fully Desktop Fabricated Flexible Graphene Electrocorticography (ECoG) Arrays 92%
Similar papers in this journal
- Electrocatalytic on-site oxygenation for transplanted cell-based-therapies 90%
- A biodegradable and restorative peripheral neural interface for the interrogation of neuropathic injuries 90%
- Micrometer-thick, porous, nanocomposite coating for electrochemical sensors with exceptional antifouling and electroconducting properties 90%
Similar papers in this journal
- A low power flexible dielectric barrier discharge disinfects surfaces and improves the action of hydrogen peroxide 91%
- Selective antibiofilm properties and biocompatibility of nano-ZnO and nano-ZnO/Ag coated surfaces 89%
- A workflow integrating organ-on-chip culture and correlative 3D light and electron microscopy for microtissue analysis 89%
Similar papers in this journal
- Rapid antifouling nanocomposite coating enables highly sensitive multiplexed electrochemical detection of myocardial infarction and concussion markers 91%
- Portable Breathing Monitoring with Phase-Resolved Airflow Dynamics Enabled by a Dual-Response Flexible PZT Sensor 89%
- Biofabrication of multiplexed electrochemical immunosensors for simultaneous detection of clinical biomarkers in complex fluids 89%
Similar papers in this journal
- Low-temperature integration of printed electrochemical sensors into OSTE+ micrfluidics for oxygen monitoring and sensing 92%
- Reversible and reusable compartmentalized microfluidic chip for coculture of dorsal root ganglion neurons 91%
- Single-cell impedance cytometry of anticancer drug-treated tumor cells exhibiting mitotic arrest state to apoptosis using low-cost silver-PDMS microelectrodes 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.