Rejuvenating silicon probes for acute electrophysiology
Shoup, A.; Porwal, N.; Fakharian, M. A.; Hage, P.; Orozco, S. P.; Shadmehr, R.
Show abstract
Electrophysiological recording with a new probe often yields better signal quality than with a used probe. Why does the signal quality degrade after only a few experiments? Here, we considered silicon probes in which the contacts are densely packed, and each is coated with a conductive polymer that increases its surface area. We tested 12 Cambridge Neurotech silicon probes during 61 recording sessions from the brain of 3 marmosets. Out of the box, each probe arrived with an electrodeposited polymer coating on 64 gold contacts, and an impedance of around 50k Ohms. With repeated use, the impedance increased and there was a corresponding decrease in the number of well-isolated neurons. Imaging of the probes suggested that the reduction in signal quality was due to a gradual loss of the polymer coating. To rejuvenate the probes, we first stripped the contacts, completely removing their polymer coating, and then recoated them in a solution of 10 mM EDOT monomer with 32 uM PSS using a current density of about 3mA/cm2 for 30 seconds. This recoating process not only returned probe impedance to around 50k Ohms, it also yielded significantly improved signal quality during neurophysiological recordings. Thus, insertion into the brain promoted loss of the polymer that coated the contacts of the silicon probes. This led to degradation of signal quality, but recoating rejuvenated the probes.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Multi-modal artificial dura for simultaneous large-scale optical access and large-scaleelectrophysiology in non-human primate cortex 95%
- TetrODrive: An open-source microdrive for combined electrophysiology and optophysiology 95%
- Characterizing the short-latency evoked response to intracortical microstimulation across a multi-electrode array 94%
Similar papers in this journal
- Synchronous Measurements of Extracellular Action Potentials and Neurochemical Activity with Carbon Fiber Electrodes in Nonhuman Primates 95%
- Small size of recorded neuronal structures confines the accuracy in direct axonal voltage measurements 93%
- Larger and denser: an optimal design for surface grids of EMG electrodes to identify greater and more representative samples of motor units 92%
Similar papers in this journal
Similar papers in this journal
- CHIME: CMOS-hosted in-vivo microelectrodes for massively scalable neuronal recordings 96%
- A fully adapted headstage for electrophysiological experiments with custom and scalable electrode arrays to record widely distributed brain regions 95%
- A head-mounted multi-camera system for electrophysiology and behavior in freely-moving mice 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.