Back

Ultra-sensitive water contaminant detection with transcription factor interfaced microcantilevers

Agarwal, D. K.; Lucci, T. J.; Jung, J. K.; Shekhawat, G. S.; Lucks, J. B.; Dravid, V. P. B.

2024-02-15 synthetic biology
10.1101/2024.02.01.578376 bioRxiv
Show abstract

Water contamination is a growing global concern, creating a need to develop technologies that can detect a range of target compounds at the required thresholds. Here, we address this need by merging biological allosteric transcription factors with DNA coated nanomechanical microcantilevers to detect chemicals in water with digital readout. After proof-of-concept demonstration and optimization to detect tetracycline with the TetR transcription factor, we use the CadC transcription factor to detect Pb2+ and Cd2+ in water at concentrations down to 2 ppb and 1 ppb, respectively, in less than fifteen minutes. A computational model suggests this improvement in sensitivity could be achieved by the DNA coated microcantilever surface changing transcription factor binding properties. Our findings demonstrate a promising new approach for water quality monitoring with fast, highly sensitive, digital readouts.

Matching journals

The top 7 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.