Labored breathing pattern: an unmeasured dimension of respiratory pathophysiology
Cyphers, V. E.; Patel, S. M.; McNamara, B. D.; Ashe, W. B.; Ratcliffe, S. J.; Moorman, J. R.; Keim-Malpass, J.; Gadrey, S. M.; Kausch, S. L.
Show abstract
IntroductionRespiratory failure is a common organ failure syndrome in hospitalized patients1. Vital sign monitoring (like respiratory rate & oximetry) is a necessary aspect of risk stratification, but it is not sufficient. In one study of hospitalized patients, 46% of the patients had no significant vital sign change in the 24 hours before an unplanned intubation2. Therefore, clinicians must also monitor for physical diagnostic signs that link the appearance of breaths to respiratory instability. Many pathognomonic patterns of high-risk labored breathing have been described. For example, when rib-dominant breaths alternate with abdomen-dominant ones, the patient is said to exhibit "respiratory alternans", a sign of inspiratory muscle overload3. However, the manual assessment of such signs lacks sensitivity, inter-rater reliability, and scalability4. We sought to (a) identify technologies that can measure labored breathing and (b) assess their readiness for clinical adoption by hospitals. MethodsWe selected four well-established diagnostic signs of labored breathing: (1) respiratory rate variability, (2) recruitment of accessory muscles (upper-rib elevation by the scalene and sternocleidomastoid muscles), (3) Abdominal Paradox (rib-abdomen asynchrony), and (4) respiratory alternans (rib-dominant breaths alternate with abdomen-dominant ones). We systematically searched PubMed using pre- specified keywords corresponding to these four signs. We identified 2868 abstracts. Two reviewers independently screened each abstract to ensure that it reported on technology that quantified the diagnostic sign of interest. A third reviewer resolved any disagreements. We excluded 2423 articles with an abstract review and included 445 articles for full paper review. We excluded an additional 127 articles after full paper review, and we were unable to acquire 4 articles. We included the remaining 314 articles for analysis. ResultsQuantification of labored breathing has been attempted for over 50 years; the earliest study included in our analysis was published in 1975. Over 30 different hardware configurations have been tried, either alone or in combination; but none of them has been validated as a comprehensive solution to measure all the four diagnostic signs that we studied. Despite enormous improvements in sensor technologies and computing capacity, the scale of investigation has not meaningfully increased since 1975. In the first decade of kinematic measurements (1975-1984), there average annual number of studies was 2.7 and the median sample size was 19. In the decade prior to our study (2013-2022), the average annual number of studies was 11.3 and the median sample size was 20. To this day, a majority of the studies are conducted in a specialized laboratories (73% between 2013-2022) rather than clinical practice settings. Most studies aimed to measure the construct validity of a technology (19%) or to describe kinematic distributions in specific clinical scenarios (77%). Rarely did studies attempt to quantify the predictive validity for a clinical outcome (4%). We did not find any clinical trial where a kinematics-based early warning intervention was tested. ConclusionsThis study describes a major bottleneck in the translation of bedside diagnostic signs of high-risk labored breathing patterns into measurable physiomarkers of respiratory instability. Despite half a century of attempted measurement, the technology readiness level for clinical adoption remains low.
Matching journals
The top 8 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Performance of EasyBreath ® Decathlon Snorkeling mask for Delivering Continuous Positive Airway Pressure 95%
- Imputation of PaO2 from SpO2 values from the MIMIC-III Critical Care Database Using Machine-Learning Based Algorithms 95%
- Kinematic signature of high-risk labored breathing revealed by novel signal analysis 94%
Similar papers in this journal
- Optimised oxygenation improves functional capacity during daily activities in patients with COPD on long-term oxygen therapy – a randomised crossover trial 92%
- Aerosol emission from the respiratory tract: an analysis of relative risks from oxygen delivery systems 92%
- Brain activity measured by functional brain imaging predicts breathlessness improvement during pulmonary rehabilitation 90%
Similar papers in this journal
- A new method to measure inter-breath intervals in infants for the assessment of apnoea and respiratory dynamics 94%
- Two-way remote monitoring allows effective and realistic provision of home-NIV to COPD patients with persistent hypercapnia 92%
- Remote-management of COPD: Evaluating Implementation of Digital Innovation to Enable Routine Care (RECEIVER) – Protocol for a feasibility and service adoption observational cohort study 92%
Similar papers in this journal
- Identification of acute exacerbations of chronic obstructive pulmonary disease using simple patient-reported symptoms and cough feature analysis: A diagnostic agreement study 95%
- A comprehensive ML-based Respiratory Monitoring System for Physiological Monitoring & Resource Planning in the ICU 94%
- Passive Detection of COVID-19 with Wearable Sensors and Explainable Machine Learning Algorithms 90%
Similar papers in this journal
- Helmet noninvasive ventilation for COVID-19 patients (Helmet-COVID): study protocol for a multicenter randomized controlled trial 93%
- COVID-19 Advanced Respiratory Care Educational Training Program for Healthcare Workers in Lesotho: An Observational Study 92%
- The Diagnostic Accuracy of Subjective Dyspnea in Detecting Hypoxemia Among Outpatients with COVID-19 92%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.