Rapid submillimeter QSM and R2* mapping using interleaved multi-shot 3D-EPI at 7 and 3 Tesla
Stirnberg, R.; Deistung, A.; Reichenbach, J. R.; Breteler, M. M. B.; Stöcker, T.
Show abstract
PurposeTo explore the high signal-to-noise ratio (SNR) efficiency of interleaved multi-shot 3D-EPI for fast and robust high-resolution whole-brain quantitative susceptibility (QSM) and [Formula] mapping at 7T and 3T. MethodsSingle- and multi-TE segmented 3D-EPI is combined with conventional CAIPIRINHA undersampling for up to 72-fold effective gradient echo (GRE) imaging acceleration. Across multiple averages, scan parameters are varied (e.g. dual-polarity frequency-encoding) to additionally correct for B0-induced artifacts, geometric distortions and motion retrospectively. A comparison to established GRE protocols is made. Resolutions range from 1.4mm isotropic (1 multi-TE average in 36s) up to 0.4mm isotropic (2 single-TE averages in approximately 6 minutes) with whole-head coverage. ResultsOnly 1-4 averages are needed for sufficient SNR with 3D-EPI, depending on resolution and field strength. Fast scanning and small voxels together with retrospective corrections result in substantially reduced image artifacts, which improves susceptibility and [Formula] mapping. Additionally, much finer details are obtained in susceptibility-weighted image projections through significantly reduced partial voluming. ConclusionUsing interleaved multi-shot 3D-EPI, single-TE and multi-TE data can readily be acquired 10 times faster than with conventional, accelerated GRE imaging. Even 0.4mm isotropic whole-head QSM within 6 minutes becomes feasible at 7T. At 3T, motion-robust and distortion-free 0.8mm isotropic whole-brain QSM and [Formula] mapping in less than 7 minutes becomes clinically feasible. Stronger gradient systems may allow for even higher effective acceleration rates through larger EPI factors while maintaining optimal contrast.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high-resolution 3D diffusion MRI 98%
- T1234: A distortion-matched structural scan solution to misregistration of high resolution fMRI data 98%
- Single-shot Echo Planar Time-resolved Imaging for multi-echo functional MRI and distortion-free diffusion imaging 98%
Similar papers in this journal
- MESMERISED: Super-accelerating T1 relaxometry and diffusion MRI with STEAM at 7 T for quantitative multi-contrast and diffusion imaging 98%
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI 98%
- Improving robustness of 3D multi-shot EPI by structured low-rank reconstruction of segmented CAIPI sampling for fMRI at 7T 96%
Similar papers in this journal
Similar papers in this journal
- Non-negative least squares computation for in vivo myelin mapping using simulated multi-echo spin-echo T2 decay data 95%
- Impact of acquisition and modeling parameters on test-retest reproducibility of edited GABA+ 95%
- Gradient scheme optimization for PRESS-localized edited MRS using weighted pathway suppression 95%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.