Back

Image-based computational fluid dynamics to compare two mitral valve reparative techniques for the prolapse

Bennati, L.; Puppini, G.; Giambruno, V.; Luciani, G.; Vergara, C.

2023-12-23 bioengineering
10.1101/2023.12.22.572827 bioRxiv
Show abstract

ObjectiveNowadays, the treatment of mitral valve prolapse involves two distinct repair techniques: chordal replacement (Neochordae technique) and leaflet resection (Resection technique). However, there is still a debate in the literature about which is the optimal one. In this context, we performed an image-based computational fluid dynamic study to evaluate blood dynamics in the two surgical techniques. MethodsWe considered a healthy subject (H) and two patients (N and R) who underwent surgery for the prolapse of the posterior leaflet and were operated with the Neochordae and Resection technique, respectively. Computational Fluid Dynamics (CFD) was employed with prescribed motion of the entire left heart coming from cine-MRI images, with a Large Eddy Simulation model to describe the transition to turbulence and a resistive method for managing valve dynamics. We created three different virtual scenarios where the operated mitral valves were inserted in the same left heart geometry of the healthy subject to study the differences attributed only to the two techniques. ResultsWe compared the three scenarios by quantitatively analyzing ventricular velocity patterns and pressures, transition to turbulence, and the ventricle ability to prevent thrombi formation. From these results we found that both the operated cases were able to restore almost physiological blood dynamic conditions, with some differences due to the reduced mobility of the Resection posterior leaflet. Conclusions: Our findings suggest that the Neochordae technique developed a slightly more physiological flow with respect to the Resection technique. The latter gave rise to a different direction of the mitral jet during diastole increasing the turbulence that is associated with ventricular effort and hemolysis, with also a larger ability to washout the ventricular apex preventing from thrombi formation.

Matching journals

The top 4 journals account for 50% of the predicted probability mass.

1
Computers in Biology and Medicine
120 papers in training set
Top 0.1%
18.8%
2
PLOS ONE
4510 papers in training set
Top 12%
14.8%
3
Biomechanics and Modeling in Mechanobiology
25 papers in training set
Top 0.1%
12.4%
4
International Journal for Numerical Methods in Biomedical Engineering
12 papers in training set
Top 0.1%
10.5%
50% of probability mass above
5
Annals of Biomedical Engineering
34 papers in training set
Top 0.2%
4.9%
6
Frontiers in Physiology
93 papers in training set
Top 0.9%
4.2%
7
Scientific Reports
3102 papers in training set
Top 29%
4.2%
8
Frontiers in Bioengineering and Biotechnology
88 papers in training set
Top 0.7%
3.1%
9
PLOS Computational Biology
1633 papers in training set
Top 11%
2.9%
10
Ultrasound in Medicine & Biology
10 papers in training set
Top 0.1%
2.9%
11
BMC Cardiovascular Disorders
14 papers in training set
Top 0.7%
2.4%
12
Journal of Biomechanical Engineering
17 papers in training set
Top 0.1%
2.1%
13
Journal of Biomechanics
57 papers in training set
Top 0.3%
2.1%
14
Frontiers in Cardiovascular Medicine
49 papers in training set
Top 2%
1.5%
15
Computer Methods and Programs in Biomedicine
27 papers in training set
Top 0.5%
1.2%
16
Bioengineering
24 papers in training set
Top 1%
0.8%
17
F1000Research
79 papers in training set
Top 6%
0.6%
18
PeerJ
261 papers in training set
Top 17%
0.6%
19
Journal of the Mechanical Behavior of Biomedical Materials
22 papers in training set
Top 0.3%
0.6%