High Inspired CO2 Target Accuracy in Mechanical Ventilation and Spontaneous Breathing Using the Additional CO2 Method

Magnusson, G.; Georgiopoulos, C.; Cedersund, G.; Tobieson, L.; Engstrom, M.

2023-11-20 radiology and imaging
10.1101/2023.11.19.23298740 medRxiv
Show abstract

Cerebrovascular Reactivity Imaging (CVR) is a diagnostic method for assessment of alterations in cerebral blood flow in response to a controlled vascular stimulus. The principal utility is the capacity to evaluate the cerebrovascular reserve, thereby elucidating autoregulatory functioning. Over the past decade, CVR has accumulated large interest, emerging as an expanding research field and application in a diverse spectrum of patient populations. In CVR, CO2 gas challenge is the most prevalent method, which elicits a vascular response by alterations in inspired CO2 concentrations. While several systems have been proposed in the literature, only a limited number have been devised to operate in tandem with mechanical ventilation, thus constraining the majority CVR investigations to spontaneous breathing individuals. We have developed a new method, denoted Additional CO2, designed to enable CO2 challenge in ventilators. The central idea is the introduction of an additional flow of highly concentrated CO2 into the respiratory circuit, as opposed to administration of the entire gas mixture from a reservoir. By monitoring the main respiratory gas flow emanating from the ventilator, the CO2 concentration in the inspired gas can be manipulated by adjusting the proportion of additional CO2. We evaluated the efficacy of this approach in controlled settings: 1) in a ventilator coupled with a test-lung and 2) in spontaneous breathing healthy volunteers. Additionally, we made a comparative analysis using a conventional method employing a gas reservoir containing a blend of O2, N2, and CO2 in varying concentrations. The methods were evaluated by assessment of the precision in attaining target inspired CO2 levels and examination of their performance within a Magnetic Resonance Imaging (MRI) environment. Our investigations revealed that the Additional CO2 method consistently achieved a high degree of accuracy in reaching target inspired CO2 levels in both mechanical ventilation and spontaneous breathing. We anticipate that these findings will lay the groundwork for a broader implementation of CVR assessments in mechanically ventilated patients.

Matching journals

The top 8 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.