Macromolecule modelling for improved metabolite quantification using short echo time brain 1H-MRS at 3 T and 7 T: The PRaMM Model
Dell'Orco, A.; Riemann, L. T.; Ellison, S. L. R.; Aydin, S.; Goeschel, L.; Tietze, A.; Scheel, M.; Fillmer, A.
Show abstract
PurposeTo improve reliability of metabolite quantification at both, 3 T and 7 T, we propose a novel parametrized macromolecules quantification model (PRaMM) for brain 1H MRS, in which the ratios of macromolecule peak intensities are used as soft constraints. MethodsFull- and metabolite-nulled spectra were acquired in three different brain regions with different ratios of grey and white matter from six healthy volunteers, at both 3 T and 7 T. Metabolite-nulled spectra were used to identify highly correlated macromolecular signal contributions and estimate the ratios of their intensities. These ratios were then used as soft constraints in the proposed PRaMM model for quantification of full spectra. The PRaMM model was validated by comparison with a single component macromolecule model and a macromolecule subtraction technique. Moreover, the influence of the PRaMM model on the repeatability and reproducibility compared to those other methods was investigated. ResultsThe developed PRaMM model performed better than the two other approaches in all three investigated brain regions. Several estimates of metabolite concentration and their Cramer-Rao lower bounds were affected by the PRaMM model reproducibility, and repeatability of the achieved concentrations were tested by evaluating the method on a second repeated acquisitions dataset. While the observed effects on both metrics were not significant, the fit quality metrics were improved for the PRaMM method (p[≤]0.0001). Minimally detectable changes are in the range 0.5 - 1.9 mM and percent coefficients of variations are lower than 10% for almost all the clinically relevant metabolites. Furthermore, potential overparameterization was ruled out. ConclusionHere, the PRaMM model, a method for an improved quantification of metabolites was developed, and a method to investigate the role of the MM background and its individual components from a clinical perspective is proposed.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Simultaneous multi-transient linear-combination modeling of MRS data improves uncertainty estimation 97%
- Fast in vivo 23Na imaging and T2* mapping using accelerated 2D-FID magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study 97%
- Musculoskeletal fat imaging and quantification by high-resolution metabolite cycling magnetic resonance spectroscopic imaging at 3 T: A fast method to generate separate distribution maps of lipid components 96%
Similar papers in this journal
- Mapping of Glutamate Metabolism using 1H FID-MRSI after oral Administration of Glc at 9.4 T 97%
- Reproducibility of 3D MRSI for imaging human brain glucose metabolism using direct ( 2 H) and indirect ( 1 H) detection of deuterium labeled compounds at 7T and clinical 3T 96%
- Quantitative T1-relaxation corrected metabolite mapping of 12 metabolites in the human brain at 9.4 T 95%