Horizon Sham Adaptor: Unlocking the Potential of Dual-Functionality of Single TMS Coil for Real and Sham Stimulations
Memarian Sorkhabi, M.
Show abstract
AO_SCPLOWBSTRACTC_SCPLOWThis paper introduces a new figure-of-eight TMS coil design capable of delivering both real and sham TMS stimulation using a single coil. The design, emitted clicking noise, and induced tactile sensation provide no discernible indication of whether it is in the real or sham state, making it suitable for double-blind studies. This coil family comprises the E-z Cool Coil and Air Film Coil (AFC) and is compatible with Magstim Horizon stimulators. This single-coil TMS setup enables the administration of either real or sham protocols without requiring coil replacement or physical repositioning. The transition between these states is achieved simply by replacing the adaptor between the coil connector and the TMS device.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Dose-Escalation Study of Amygdalar Transcranial Focused Ultrasound in Healthy Volunteers 93%
- Towards individualized deep brain stimulation: A stereoelectroencephalography-based workflow for neurostimulation target identification 91%
- High-resolution computational modeling of Transcranial Photobiomodulation: Light propagation and thermal effects 91%
Similar papers in this journal
- Non-invasive stimulation with Temporal Interference: Optimization of the electric field deep in the brain with the use of a genetic algorithm 97%
- Magnetic Temporal Interference for Noninvasive Focal Brain Stimulation 97%
- Measuring Transcranial Magnetic Stimulation-Induced Electric Fields in Anatomically and Conductively Accurate Rat Head Phantoms 96%
Similar papers in this journal
Similar papers in this journal
- Impact of galvanic vestibular stimulation electrode current density on brain current flow patterns: Does electrode size matter? 97%
- Detailed measurements and simulations of electric field distribution of two TMS coils cleared for obsessive compulsive disorder in the brain and in specific regions associated with OCD 96%
- Reconfigurable MRI coil technology can substantially reduce RF heating at the tips of bilateral deep brain stimulation implants 96%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.