Development of an MR-guided focused ultrasound (MRgFUS) lesioning approach for small and deep structures in the rat brain
Cornelssen, C.; Payne, A.; Parker, D.; Alexander, M.; Merrill, R.; Senthilkumar, S.; Christensen, J.; Wilcox, K. S.; Odeen, H.; Rolston, J. D.
Show abstract
ObjectiveHigh-intensity magnetic resonance-guided focused ultrasound (MRgFUS) is a noninvasive therapy to lesion brain tissue, used clinically in patients and preclinically in several animal models. Challenges with focused ablation in rodent brains can include skull and near-field heating and accurately targeting small and deep brain structures. We overcame these challenges by creating a novel method consisting of a craniectomy skull preparation, a high-frequency transducer (3 MHz) with a small ultrasound focal spot, a transducer positioning system with an added manual adjustment of [~]0.1 mm targeting accuracy, and MR acoustic radiation force imaging for confirmation of focal spot placement. MethodsThe study consisted of two main parts. First, two skull preparation approaches were compared. A skull thinning approach (n=7 lesions) was compared to a craniectomy approach (n=22 lesions), which confirmed a craniectomy was necessary to decrease skull and near-field heating. Second, the two transducer positioning systems were compared with the fornix chosen as a subcortical ablation target. We evaluated the accuracy of targeting using a high-frequency transducer with a small ultrasound focal spot and MR acoustic radiation force imaging. ResultsComparing a motorized adjustment system ([~]1 mm precision, n=17 lesions) to the motorized system with an added micromanipulator ([~]0.1 mm precision, n=14 lesions), we saw an increase in the accuracy of targeting the fornix by 133%. The described work allows for repeatable and accurate targeting of small and deep structures in the rodent brain, such as the fornix, enabling the investigation of neurological disorders in chronic disease models.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Histologic safety of transcranial focused ultrasound neuromodulation and magnetic resonance acoustic radiation force imaging in rhesus macaques and sheep 96%
- Safety of Focused Ultrasound Neuromodulation in Humans with Temporal Lobe Epilepsy 94%
- TI-Toolbox: An Open-Source Software for Temporal Interference Stimulation Research 93%
Similar papers in this journal
- Measuring Transcranial Magnetic Stimulation-Induced Electric Fields in Anatomically and Conductively Accurate Rat Head Phantoms 93%
- TAP: Targeting and analysis pipeline for optimization and verification of coil placement in transcranial magnetic stimulation 93%
- Laser Ablation of the Pia Mater for Insertion of High-Density Microelectrode Arrays in a Translational Sheep Model 93%
Similar papers in this journal
- Detailed measurements and simulations of electric field distribution of two TMS coils cleared for obsessive compulsive disorder in the brain and in specific regions associated with OCD 95%
- Vibrotactile auricular vagus nerve stimulation alters limbic system connectivity in humans: A pilot study 93%
- Increased brain coverage and efficiency when measuring current-induced magnetic fields by use of simultaneous multi-slice echo-planar MRI 92%
Similar papers in this journal
- Real Time and Delayed Effects of Subcortical Low Intensity Focused Ultrasound 93%
- Interventional Neurorehabilitation for Promoting Functional Recovery Post-Craniotomy: A Proof-of-Concept 93%
- Probabilistic comparison of gray and white matter coverage between depth and surface intracranial electrodes in epilepsy: a patient-specific modeling and empirical study 93%
Similar papers in this journal
- In vivo visualization of pig vagus nerve 'vagotopy' using ultrasound 92%
- Interest of tri-axial rubidium and helium optically pumped magnetometers for on-scalp magnetoencephalography recording of interictal epileptiform discharges 92%
- Quantitative evaluation of normal cerebrospinal fluid flow in the Sylvian aqueduct and perivascular spaces of the middle cerebral artery and circle of Willis via 2D phase-contrast MR imaging 91%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.