In vivo disentanglement of diffusion frequency-dependence, tensor shape, and relaxation using multidimensional MRI
Johnson, J. T. E.; Irfanoglu, M. O.; Manninen, E.; Ross, T. J.; Yang, Y.; Laun, F. B.; Martin, J.; Topgaard, D.; Benjamini, D.
Show abstract
Diffusion MRI with free gradient waveforms, combined with simultaneous relaxation encoding, referred to as multidimensional MRI (MD-MRI), offers microstructural specificity in complex biological tissue. This approach delivers intravoxel information about the microstructure, local chemical composition, and importantly, how these properties are coupled within heterogeneous tissue containing multiple microenvironments. Recent theoretical advances incorporated diffusion time dependency and integrated MD-MRI with concepts from oscillating gradients. This framework probes the diffusion frequency,{omega} , in addition to the diffusion tensor, D, and relaxation, R1, R2, correlations. A D({omega})-R1-R2 clinical imaging protocol was then introduced, with limited brain coverage and 3 mm3 voxel size, which hinder brain segmentation and future cohort studies. In this study, we introduce an efficient, sparse in vivo MD-MRI acquisition protocol providing whole brain coverage at 2 mm3 voxel size. We demonstrate its feasibility and robustness using a well-defined phantom and repeated scans of five healthy individuals. Additionally, we test different denoising strategies to address the sparse nature of this protocol, and show that efficient MD-MRI encoding design demands a nuanced denoising approach. The MD-MRI framework provides rich information that allows resolving the diffusion frequency dependence into intravoxel components based on their D({omega})-R1-R2 distribution, enabling the creation of microstructure-specific maps in the human brain. Our results encourage the broader adoption and use of this new imaging approach for characterizing healthy and pathological tissues.
Matching journals
The top 2 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- In vivo Correlation Tensor MRI reveals microscopic kurtosis in the human brain on a clinical 3T scanner 98%
- Error quantification in multi-parameter mapping facilitates robust estimation and enhanced group level sensitivity 98%
- On the generalizability of diffusion MRI signal representations across acquisition parameters, sequences and tissue types: chronicles of the MEMENTO challenge. 98%
Similar papers in this journal
- Axisymmetric diffusion kurtosis imaging with Rician bias correction: A simulation study 97%
- Attenuation of Motion Artifacts in fMRI using Discrete Reconstruction of Irregular fMRI Trajectories (DRIFT) 97%
- QSM Reconstruction Challenge 2.0: a realistic in silico head phantom for MRI data simulation and evaluation of susceptibility mapping procedures 96%
Similar papers in this journal
- Human gray matter microstructure mapped using Neurite Exchange Imaging (NEXI) on a clinical scanner 98%
- Denoising Diffusion MRI: Considerations and implications for analysis 98%
- ACID: A Comprehensive Toolbox for Image Processing and Modeling of Brain, Spinal Cord, and Post-mortem Diffusion MRI Data 97%
Similar papers in this journal
- Visualizing orientation-specific relaxation-diffusion features mapped onto orientation distribution functions estimated via nonparametric Monte Carlo MRI signal inversion 98%
- Diffusion MRI Head Motion Correction Methods are Highly Accurate but Impacted by Denoising and Sampling Scheme 97%
- Reproducibility and reliability of Free-Water-corrected Diffusion Tensor Imaging of the brain: Revisited 97%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.