Deriving Explainable Metrics of Left Ventricular Flow by Reduced-Order Modeling and Classification
Borja, M. G.; Martinez-Legazpi, P.; Nguyen, C.; Flores, O.; Kahn, A. M.; Bermejo, J.; del Alamo, J. C.
Show abstract
BackgroundExtracting explainable flow metrics is a bottleneck to the clinical translation of advanced cardiac flow imaging modalities. We hypothesized that reduced-order models (ROMs) of intraventricular flow are a suitable strategy for deriving simple and interpretable clinical metrics suitable for further assessments. Combined with machine learning (ML) flow-based ROMs could provide new insight to help diagnose and risk-stratify patients. MethodsWe analyzed 2D color-Doppler echocardiograms of 81 non-ischemic dilated cardiomyopathy (DCM) patients, 51 hypertrophic cardiomyopathy (HCM) patients, and 77 normal volunteers (Control). We applied proper orthogonal decomposition (POD) to build patient-specific and cohort-specific ROMs of LV flow. Each ROM aggregates a low number of components representing a spatially dependent velocity map modulated along the cardiac cycle by a time-dependent coefficient. We tested three classifiers using deliberately simple ML analyses of these ROMs with varying supervision levels. In supervised models, hyperparameter gridsearch was used to derive the ROMs that maximize classification power. The classifiers were blinded to LV chamber geometry and function. We ran vector flow mapping on the color-Doppler sequences to help visualize flow patterns and interpret the ML results. ResultsPOD-based ROMs stably represented each cohort through 10-fold cross-validation. The principal POD mode captured >80% of the flow kinetic energy (KE) in all cohorts and represented the LV filling/emptying jets. Mode 2 represented the diastolic vortex and its KE contribution ranged from <1% (HCM) to 13% (DCM). Semi-unsupervised classification using patient-specific ROMs revealed that the KE ratio of these two principal modes, the vortex-to-jet (V2J) energy ratio, is a simple, interpretable metric that discriminates DCM, HCM, and Control patients. Receiver operating characteristic curves using V2J as classifier had areas under the curve of 0.81, 0.91, and 0.95 for distinguishing HCM vs. Control, DCM vs. Control, and DCM vs. HCM, respectively. ConclusionsModal decomposition of cardiac flow can be used to create ROMs of normal and pathological flow patterns, uncovering simple interpretable flow metrics with power to discriminate disease states, and particularly suitable for further processing using ML.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Super-resolution Left Ventricular Flow and Pressure Mapping by Navier-Stokes-Informed Neural Networks 95%
- Pulmonary vein flow split effects in patient-specific simulations of left atrial flow 95%
- Uncertainty in cardiovascular digital twins despite non-normal errors in 4D flow MRI: identifying reliable biomarkers such as ventricular relaxation rate 94%
Similar papers in this journal
- Predicting Ventricular Tachycardia Circuits in Patients with Arrhythmogenic Right Ventricular Cardiomyopathy using Genotype-specific Heart Digital Twins 95%
- Personalized Computational Modeling Identifies Embolic Stroke of Undetermined Source Patients with Potential Arrhythmic Substrate 90%
- 3D virtual Histopathology of Cardiac Tissue from Covid-19 Patients based on Phase-Contrast X-ray Tomography 89%
Similar papers in this journal
- BRAVEHEART: Open-source software for automated electrocardiographic and vectorcardiographic analysis 93%
- Automated IntraVascular UltraSound Image Processing and Quantification of Coronary Artery Anomalies: The AIVUS-CAA software 93%
- Computational hemodynamic indices to identify Transcatheter Aortic Valve Implantation degeneration 92%
Similar papers in this journal
- Multimodal deep learning enhances diagnostic precision in left ventricular hypertrophy 94%
- Automated Echocardiographic Detection of Mitral Valve Prolapse and Mitral Regurgitation with Video-based Artificial Intelligence Algorithms 93%
- Simple Models Versus Deep Learning in Detecting Low Ejection Fraction From The Electrocardiogram 93%
Similar papers in this journal
- A Deep Learning Algorithm for Automated Cardiac Murmur Detection Via a Digital Stethoscope Platform 91%
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 91%
- The HeartMagic prospective observational study protocol - characterizing subtypes of heart failure with preserved ejection fraction 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.