Deep Learning-enabled Detection of Aortic Stenosis from Noisy Single Lead Electrocardiograms
Aminorroaya, A.; Dhingra, L. S.; Sangha, V.; Oikonomou, E. K.; Khunte, A.; Shankar, S. V.; Camargos, A. P.; Haynes, N.; Hofer, I.; Ouyang, D.; Nadkarni, G.; Khera, R.
Show abstract
BackgroundDue to the lack of a feasible screening strategy, aortic stenosis (AS) is often diagnosed after the development of clinical symptoms, representing advanced stages of disease. Portable and wearable devices capable of recording electrocardiograms (ECGs) can be used for scalable screening for AS, if the diagnosis can be made with a single-lead ECG, despite potentially noisy acquisition. MethodsUsing electronic health records and imaging data from a large, diverse hospital system (2015-2022), we developed a deep learning-based approach to detect moderate/severe AS using a single-lead ECG. We used ECGs paired with echocardiograms obtained within 30 days of each other to develop the model. We extracted lead I signal data from clinical ECG and augmented it with random Gaussian noise. We trained a convolutional neural network (CNN) to identify TTE-confirmed AS using noisy single-lead ECGs. Finally, we used the CNN model probabilities, along with patient age and sex, as predictive inputs to train an extreme gradient boosting (XGBoost) model to detect moderate/severe AS. ResultsThe model was developed in 75,901 ECGs/35,992 patients (median age 61 [interquartile range (IQR) 47-72] years, 54.3% women, 9.5% Black) and validated in 3,733 patients (median age 61 [IQR 47-72] years, 53.4% women, 9.7% Black). In the held-out validation set, the ensemble XGBoost model achieved an AUROC of 0.829 (95% CI: 0.800-0.855), with a sensitivity of 90.4% and specificity of 58.7% for detecting moderate/severe AS. For detecting severe AS, the models AUROC was 0.846 (95% CI, 0.778-0.899), with a sensitivity of 94.3% and specificity of 57.0%. In the test set with a 4.5% prevalence of moderate/severe AS, the model had a PPV of 9.3% and an NPV of 99.2%. In simulated cohorts with 1% and 20% prevalence of moderate/severe AS, the models NPVs varied from 99.8% to 96.1%, and PPV from 2.2% to 35.4%, respectively. ConclusionWe developed a novel portable- and wearable-adapted deep learning approach for the detection of moderate/severe AS from noisy single-lead ECGs. Our approach represents a highly sensitive, feasible, and scalable strategy for community-based AS screening.
Matching journals
The top 3 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Simple Models Versus Deep Learning in Detecting Low Ejection Fraction From The Electrocardiogram 97%
- Development and Multinational Validation of an Ensemble Deep Learning Algorithm for Detecting and Predicting Structural Heart Disease Using Noisy Single-lead Electrocardiograms 97%
- International Evaluation Of An Artificial Intelligence-Powered Ecg Model Detecting Occlusion Myocardial Infarction 96%
Similar papers in this journal
- Algorithm for Predicting Valvular Heart Disease from Heart Sounds in an Unselected Cohort 98%
- Fairness in Cardiac Magnetic Resonance Imaging: Assessing sex and racial bias in deep learning-based segmentation 94%
- Deep learning-based end-to-end automated stenosis classification and localization on catheter coronary angiography 94%
Similar papers in this journal
- Smartwatch Facilitated Remote Health Care for Patients Undergoing Transcatheter Aortic Valve Replacement Amid COVID-19 Pandemic 94%
- Non-Invasive Scale Measurement of Cardiac Output Compared with the Gold-Standard Direct Fick Method: A Feasibility Study 94%
- Artificial intelligence of arterial Doppler waveforms to predict major adverse outcomes among patients evaluated for peripheral artery disease 93%
Similar papers in this journal
- Investigating Electrocardiographic Abnormalities in Patients with Coronary Microvascular Dysfunction 95%
- A Multicenter Evaluation of the Impact of Procedural and Pharmacological Interventions on Deep Learning-based Electrocardiographic Markers of Hypertrophic Cardiomyopathy 94%
- Prognostic value of compact myocardial thinning in patients with left ventricular non-compaction 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.