Preliminary cross-sectional investigations into the human glymphatic system using multiple novel non-contrast MRI methods.
Levendovszky, S. R.; Flores, J. R.; Peskind, E.; Vaclavu, L.; van Osch, M. J. P.; Iliff, J. J.
Show abstract
We discuss two potential non-invasive MRI methods to cross-sectionally study two distinct facets of the glymphatic system and its association with sleep and aging. We apply diffusion-based intravoxel incoherent motion (IVIM) imaging to evaluate pseudodiffusion coefficient, D*, or cerebrospinal fluid (CSF) movement across large spaces like the subarachnoid space (SAS). We also performed perfusion-based multi-echo, Hadamard encoded multi-delay arterial spin labeling (ASL) to evaluate whole brain cortical cerebral blood flow (CBF) and transendothelial exchange (Tex) of water from the vasculature into the perivascular space and parenchyma. Both methods were used in young adults (N=9, 6F, 23{+/-}3 years old) in the setting of sleep and sleep deprivation. To study aging, 10 older adults, (6F, 67{+/-}3 years old) were imaged after a night of normal sleep only and compared with the young adults. D* in SAS was significantly (p<0.05) lesser after sleep deprivation (0.014{+/-}0.001 mm2/s) than after normal sleep (0.016{+/-}0.001 mm2/s), but was unchanged with aging. Cortical CBF and Tex on the other hand, were unchanged after sleep deprivation but were significantly lower in older adults (37{+/-}3 ml/100g/min, 476{+/-}66 ms) than young adults (42{+/-}2 ml/100g/min, 624{+/-}66 ms). IVIM was thus, sensitive to sleep physiology and multi-echo, multi-delay ASL was sensitive to aging.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Combining Navigator and Optical Prospective Motion Correction for High-Quality 500 μm Resolution Quantitative Multi-Parameter Mapping at 7T 94%
- Neuroanatomical underpinning of diffusion kurtosis measurements in the cerebral cortex of healthy macaque brains 93%
- Ultrafast fMRI detects age-related changes in harmonics of cardiac pulsations in the brain at 7 T 93%
Similar papers in this journal
Similar papers in this journal
- Brain Iron Imaging Markers in the Presence of White Matter Hyperintensities 93%
- Increased Brain Volumetric Measurement Precision from Multi-Site 3D T1-weighted 3T Magnetic Resonance Imaging by Correcting Geometric Distortions 92%
- Influence of preprocessing, distortion correction and cardiac triggering on the quality of diffusion MR images of spinal cord 92%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.