Voxel-wise regression without intensity normalizationprovides better sensitivity when identifying injuryregions after stroke in FDG-PET images
WUXIAN, H.; Tang, H.; Li, J.; Shen, X.; Zhang, X.; Li, C.; Liu, H.; Yu, W.
Show abstract
BackgroundIn the analysis of brain fluorodeoxyglucose positron emission tomography (FDG-PET), intensity normalization is a necessary step to reduce inter-subject variability. However, the choice of an appropriate normalization method in stroke studies remains unclear, leading to inconsistent findings in the literature. Materials and methodsHere, we propose a regression-based and single-subject-based model for analyzing FDG-PET images without intensity normalization. Two independent data sets were collected before and after middle cerebral artery occlusion (MCAO), with one comprising 120 rats and the other comprising 96 rats. After data preprocessing, voxel intensities in the same region and hemisphere were paired before and after the MCAO scan. A linear regression model was applied to the paired data, and the coefficient of determination was calculated to measure the linearity. The results between the ipsilateral and contralateral hemispheres were compared, and significant regions were defined as those having reduced linearity. Our method was compared with existing intensity normalization methods and validated using the triphenyl tetrazolium chloride (TTC) staining data. ResultsThe proposed method detected more injury areas compared to existing approaches, as confirmed by the ground truth provided by TTC. The area under the curve (AUC) of the average receiver operating characteristic (ROC) curves using our method reached 0.84, whereas the AUCs using existing methods ranged from 0.77 [~] 0.79. The average false positive rate (FPR) and true positive rate (TPR) of the individual analysis results using our method (FPR = 0.06, TPR = 0.56) were better than the group-wise analysis results using t-tests (FPR = 0.10, TPR = 0.51). The identified injury regions were consistent in the two independent data sets. Some of them were confirmed by other publications. ConclusionsThe proposed method offers a new quantitative approach to analyzing FDG-PET images. The calculation does not involve intensity normalization and can be applied to a single subject. The method yields more sensitive results than existing intensity normalization methods.
Matching journals
The top 7 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Cerebral artery segmentation based on magnetization-prepared two rapid acquisition gradient echo multi-contrast images in 7 Tesla magnetic resonance imaging 95%
- Vessel Density Mapping of Cerebral Small Vessels on 3D High Resolution Black Blood MRI 94%
- Analysis of continuous infusion functional PET (fPET) in the human brain 94%
Similar papers in this journal
- A Multicenter Preclinical MRI Study: Definition of Rat Brain Relaxometry Reference Maps 94%
- Magia: Robust automated image processing and kinetic modeling toolbox for PET neuroinformatics 93%
- Neural Network-derived perfusion maps: a Model-free approach to computed tomography perfusion in patients with acute ischemic stroke 93%
Similar papers in this journal
- Quantitative evaluation of normal cerebrospinal fluid flow in the Sylvian aqueduct and perivascular spaces of the middle cerebral artery and circle of Willis via 2D phase-contrast MR imaging 93%
- Cortical thickness estimation in individuals with cerebral small vessel disease, focal atrophy, and chronic stroke lesions. 93%
- Probabilistic atlas of the lateral parabrachial nucleus, medial parabrachial nucleus, vestibular nuclei complex and medullary viscero-sensory-motor nuclei complex in living humans from 7 Tesla MRI 92%
Similar papers in this journal
- GABA quantification in human anterior cingulate cortex 93%
- Differential effects of aquaporin-4 channel inhibition on BOLD fMRI and Diffusion fMRI responses in rat visual cortex 92%
- Improved Inter-Subject Alignment of the Lumbosacral Cord for Group-Level In Vivo Gray and White Matter Assessments: A Scan-Rescan MRI Study at 3T 92%
Similar papers in this journal
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.