Soft robotics-enabled large animal model of HFpEF hemodynamics for device testing
Rosalia, L.; Ozturk, C.; Wang, S.; Quevedo, D.; Saeed, M.; Mauskapf, A.; Roche, E.
Show abstract
Heart failure with preserved ejection fraction (HFpEF) is a major challenge in cardiovascular medicine, accounting for approximately 50% of all cases of heart failure. Due to the lack of effective therapies for this condition, the mortality associated with HFpEF remains higher than that of most cancers. Despite the ongoing efforts, no medical device has yet received FDA approval. This is largely due to the lack of an in vivo model of the HFpEF hemodynamics, resulting in the inability to evaluate device effectiveness in vivo prior to clinical trials. Here, we describe the development of a highly tunable porcine model of HFpEF hemodynamics using implantable soft robotic sleeves, where controlled actuation of a left ventricular and an aortic sleeve can recapitulate changes in ventricular compliance and afterload associated with a broad spectrum of HFpEF hemodynamic phenotypes. We demonstrate the feasibility of the proposed model in preclinical testing by evaluating the hemodynamic response of the model post-implantation of an interatrial shunt device, which was found to be consistent with findings from in silico studies and clinical trials. This work addresses several of the limitations associated with previous models of HFpEF, such as their limited hemodynamic fidelity, elevated costs, lengthy development time, and low throughput. By showcasing exceptional versatility and tunability, the proposed platform has the potential to revolutionize the current approach for HFpEF device development and selection, with the goal of improving the quality of life for the 32 million people affected by HFpEF worldwide.
Matching journals
The top 10 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Simultaneous assessment of mechanical and electrical function in Langendorff-perfused ex-vivo mouse heart 95%
- Improved Hemodynamic Performance and Reduced Paravalvular Regurgitation with the SAPIEN 3 Ultra RESILIA Valve: A Propensity-Matched Single-Center TAVR Study 93%
- Autologous cardiac micrografts as support therapy to coronary artery bypass surgery 93%
Similar papers in this journal
- Predicting Ventricular Tachycardia Circuits in Patients with Arrhythmogenic Right Ventricular Cardiomyopathy using Genotype-specific Heart Digital Twins 93%
- Ryanodine receptor 2 inhibition reduces dispersion of cardiac repolarization, improves contractile function and prevents sudden arrhythmic death in failing hearts 92%
- Personalized Computational Modeling Identifies Embolic Stroke of Undetermined Source Patients with Potential Arrhythmic Substrate 92%
Similar papers in this journal
Similar papers in this journal
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 94%
- Genetic ablation of serotonin receptor 2B improves aortic valve hemodynamics in a high-cholesterol diet mouse model 93%
- High-resolution Spatiotemporal Changes in Dominant Frequency and Structural Organization During Persistent Atrial Fibrillation 93%
Similar papers in this journal
- Tricuspid valve leaflet remodeling in sheep with biventricular heart failure: A comparison between leaflets 95%
- Characterization of pediatric porcine pulmonary valves as a model for tissue engineered heart valves 94%
- Structural and Mechanical Analysis of Treated and Untreated Aortic Coarctation in a Growing Porcine Model 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.