Radial and Axial Fractional Shortening for Rapid Estimation of Left Ventricular Ejection Fraction: A Computational Analysis
Rifkin, R. D.; Rich, M. W.
Show abstract
BACKGROUND AND PURPOSESimpson Rule based planimetry remains the gold standard for left ventricular (LV) ejection fraction (EF) but due to sub-optimal endocardial delineation, planimetry is not feasible in many cases. The purpose of this study was to derive and to analytically evaluate the theoretical accuracy of several simple novel formulas for estimating EF in ventricles with uniform wall motion using only the radial diameter and axial length LV fractional shortening (FD and FL respectively), which are less subject to image quality limitations than planimetry. METHODSA truncated ellipsoidal model of the LV at end-diastole and end-systole was assumed leading to a novel compact formula for directly calculating an exact EF that is identical to the Simpson Rule EF when the ventricle has ellipsoidal end-diastolic (ED) and end-systolic (ES) shapes. O_FD O_INLINEFIG[Formula]C_INLINEFIGC_FD Three linear formulas were then developed to directly calculate an approximation to the exact EF without intermediate calculation of volumes. To avoid population selection bias in this initial investigation the linear coefficients were determined by an analytic graphical optimization procedure that minimized the EF errors compared to the exact EF over the full range of exact EFs from 0 to 80% (FD and FL in percent). O_FD O_INLINEFIG[Formula]C_INLINEFIGC_FD RESULTSIn single factor linear approximations #1 and #2, the EF difference from the exact EF was dependent on the ratio FL/ FD, which is normally between 40 and 50%. Subject to the assumption of ellipsoidal LV shape at ED and ES, for ratios of FL/ FD between 20% and 80%, and over EFs ranging from 0 to 55%, the calculated differences from the exact EF were less than 6 EF points. At extremes of the ratio, less than 20% or over 80%, or for EFs over 55%, the difference could reach or exceed 10 points. Formula #2 produced slightly smaller differences than formula #1. Formula #3 reduced the difference error substantially to less than 4 EF percentage points regardless of the FL/ FD ratio except at EFs over 75%. CONCLUSIONSIn uniformly contracting ventricles, simple linear formulas could provide rapid estimation of EF and may be helpful when image quality degrades planimetric EF accuracy, as well as in point-of-care echocardiography where planimetry is not feasible. Validation of these formulas through empirical testing is warranted.
Matching journals
The top 6 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Mechanical effects of MitraClip on leaflet stress and myocardial strain in functional mitral regurgitation: A finite element modeling study. 96%
- {-}CardiOvascular examination in awake Orangutans (Pongo pygmaeus pygmaeus): Low-stress Echocardiography including Speckle Tracking imaging (the COOLEST method) 95%
- Ventricular anatomical complexity and gender differences impact predictions from computational models 94%
Similar papers in this journal
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part I: Establishing Credibility of an Advanced Model 95%
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration 94%
- Digitizing ECG image: new fully automated method and open-source software code 94%
Similar papers in this journal
- Referral for Cardiac Amyloidosis in Patients who underwent Transcatheter Aortic Valve Replacement: Result of Quality Outcome Project 92%
- Comparison of in-hospital mortality and clinical outcomes among patients greater than and less than 80 years undergoing TAVR 90%
- Hospitalist perspectives of available tests to monitor volume status in patients with heart failure: a qualitative study 90%
Similar papers in this journal
- Patient-specific analysis of bicuspid aortic valve hemodynamics using a fully coupled fluid-structure interaction (FSI) model 95%
- Pulmonary vein flow split effects in patient-specific simulations of left atrial flow 94%
- Detecting Heart Failure using novel bio-signals and a Knowledge Enhanced Neural Network 93%
Similar papers in this journal
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 94%
- Impact of residual intimal flap displacement post-TEVAR on TBAD haemodynamics in compliant, patient-specific CFD simulations informed by MRI 94%
- Quantitative Assessment of Aortic Hemodynamics for Varying Left Ventricular Assist Device Outflow Graft Angles and Flow Pulsation 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.