Non-Endoscopic Esophageal Sampling Device And Biomarker Panel For Detection Of Barrett'S Esophagus (Be) And Esophageal Adenocarcinoma (Eac)
Moinova, H. R.; Verma, S.; Dumot, J.; Faulx, A.; Iyer, P. G.; Canto, M. I.; Wang, J. S.; Shaheen, N. J.; Thota, P. N.; Aklog, L.; Willis, J. E.; Markowitz, S. D.; Chak, A.
Show abstract
BACKGROUNDWe previously reported an encapsulated balloon (EsoCheckTM, EC), which selectively samples the distal esophagus, that coupled with a two methylated DNA biomarker panel (EsoGuardTM, EG), detected Barretts esophagus (BE) and esophageal adenocarcinoma (EAC), with a sensitivity and specificity of 90.3% and 91.7%, respectively. This previous study utilized frozen EC samples. AIMTo assess a next generation EC sampling device and EG assay that utilizes a room temperature sample preservative to enable office-based testing. METHODSCases with nondysplastic (ND) and dysplastic (indefinite=IND, low grade dysplasia = LGD, high grade dysplasia = HGD) BE, EAC, junctional adenocarcinoma (JAC) and controls with no intestinal metaplasia (IM) were included. Nurses or physician assistants at six institutions, who were trained in EC administration, delivered the encapsulated balloon per orally and inflated it in the stomach. The inflated balloon was pulled back to sample 5 cm of the distal esophagus, then deflated and retracted into the EC capsule to prevent sample contamination from proximal esophagus. Nextgen EG sequencing assays performed on bisulfite-treated DNA extracted from EC samples determined levels of methylated Vimentin (mVIM) and methylated Cyclin A1 (mCCNA1) in a CLIA-certified laboratory, blinded to patients phenotypes. RESULTSA total of 243 evaluable patients - 88 cases (median age 68 years, 78% men, 92% white) and 155 controls (median age 57 years, 41% men, 88% white) - underwent adequate EC sampling. Mean time for EC sampling was just over 3 minutes. The cases included 31 NDBE, 16 IND/LGD, 23 HGD, and 18 EAC/JAC. Thirty-seven (53%) of the non-dysplastic and dysplastic BE cases were short-segment BE (SSBE; < 3 cm). Overall sensitivity for detecting all cases was 85% (95% CI= 0.78-0.93) and specificity was 85% (95% CI=0.79-0.90). Sensitivity for NDBE was 84% (n=37). The EC/EG test detected 100% of cancers. CONCLUSIONThe next-generation EC/EG technology has been both successfully updated to incorporate a room temperature sample collection preservative and successfully implemented in a CLIA certified laboratory. When performed by trained personnel, EC/EG detects non-dysplastic BE, dysplastic BE, and cancer with high sensitivity and specificity, replicating the operating characteristics of the initial pilot study of this technology. Future applications utilizing EC/EG to screen broader populations at risk for developing cancer are proposed. SIGNIFICANCEThis multi-center study demonstrates the successful performance of a commercially available clinically implementable non-endoscopic screening test for BE in the U.S., as recommended in the most recent ACG Guideline and AGA Clinical Update. It transitions and validates a prior academic laboratory-based study of frozen research samples over to a CLIA laboratory, one that also integrates a clinically practical room temperature method for sample acquisition and storage, enabling office-based screening.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Analytical performance of a highly sensitive system to detect gene variants using next-generation sequencing for lung cancer companion diagnostics 89%
- Preclinical and clinical validation of a novel injected molded swab for molecular assay detection of SARS-CoV-2 virus 88%
- Deep learning models for poorly differentiated colorectal adenocarcinoma classification in whole slide images using transfer learning 87%
Similar papers in this journal
Similar papers in this journal
- Non-endoscopic screening for Barrett’s esophagus and Esophageal Adenocarcinoma in at risk Veterans 97%
- Nonendoscopic Detection Of Barrett’S Esophagus In Patients Without Gerd Symptoms 96%
- Normative values for body surface gastric mapping evaluations of gastric motility using Gastric Alimetry: spectral analysis 91%
Similar papers in this journal
- Histopathologist Features Predictive of Diagnostic Concordance at Expert Level Amongst a Large International Sample of Pathologists Diagnosing Barrett′s Dysplasia Using Digital Pathology 93%
- Barrett's esophagus is the precursor of all esophageal adenocarcinomas 92%
- Multi-centre derivation and validation of a colitis-associated colorectal cancer risk prediction web-tool 92%
Similar papers in this journal
- Aerodigestoscopy (ADS): A retrospective examination of the feasibility, safety, and comfort of a new procedure for the evaluation of physiological disorders of the aerodigestive tract 92%
- Artificial Intelligence in laryngeal endoscopy: Systematic Review and Meta-Analysis 89%
- Efficacy of AI-assisted personalized microbiome modulation by diet in functional constipation: a randomized controlled trial 89%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.