Alpha-180 spin-echo based line-scanning method for high resolution laminar-specific fMRI
Choi, S.; Hike, D.; Pohmann, R.; Avdievitch, N. I.; Scheffler, K.; Yu, X.
Show abstract
Laminar-specific functional magnetic resonance imaging (fMRI) has been widely used to study circuit-specific neuronal activity by mapping spatiotemporal fMRI response patterns across cortical layers. Hemodynamic responses reflect indirect neuronal activity given limit of spatial and temporal resolution. Previous gradient-echo based line-scanning fMRI (GELINE) method was proposed with high temporal (50 ms) and spatial (50 {micro}m) resolution to better characterize the fMRI onset time across cortical layers by employing 2 saturation RF pulses. However, the imperfect RF saturation performance led to poor boundary definition of the reduced region of interest (ROI) and aliasing problems outside of the ROI. Here, we propose (alpha)-180 spin-echo-based line-scanning fMRI (SELINE) method to resolve this issue by employing a refocusing 180{degrees} RF pulse perpendicular to the excitation slice. In contrast to GELINE signals peaked at the superficial layer, we detected varied peaks of laminar-specific BOLD signals across deeper cortical layers with the SELINE method, indicating the well-defined exclusion of the large drain-vein effect with the spin-echo sequence. Furthermore, we applied the SELINE method with 200 ms TR to sample the fast hemodynamic changes across cortical layers with a less draining vein effect. In summary, this SELINE method provides a novel acquisition scheme to identify microvascular-sensitive laminar-specific BOLD responses across cortical depth.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI 95%
- Zero-echo time imaging achieves whole brain activity mapping without ventral signal loss in mice 95%
- Whole-brain studies of spontaneous behavior in head-fixed rats enabled by zero echo time MB-SWIFT fMRI 95%
Similar papers in this journal
- Sampling strategies and integrated reconstruction for reducing distortion and boundary slice aliasing in high-resolution 3D diffusion MRI 95%
- Spherical Echo-Planar Time-resolved Imaging (sEPTI) for rapid 3D quantitative T2* and Susceptibility imaging 95%
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice 94%
Similar papers in this journal
- TMS with fast and accurate electronic control: measuring the orientation sensitivity of corticomotor pathways 93%
- Transcranial direct current stimulation elevates the baseline activity while sharpening the spatial tuning of the human visual cortex 93%
- Hemodynamic changes in response to excitatory and inhibitory modulations by transcranial magnetic stimulation at the human sensorimotor cortex 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.