Comparison of shear stress patterns by the established and advanced reconstruction method incorporating side branches to predict plaque progression
Ramasamy, A.; Räber, L.; Tanboga, I. h.; Safi, H.; Hadjiandreou, M.; Sakellarios, A.; Kitslaar, P. H.; Dijkstra, J.; Biccire, F. G.; Crake, T.; Michalis, L. K.; Fotiadis, D.; Windecker, S.; Zhang, Y.-J.; Mathur, A.; Baumbach, A.; Torii, R.; Bourantas, C. V.
Show abstract
BackgroundComplete vessel reconstruction (CVR) with incorporation of side branches is essential for accurate evaluation of wall shear stress (WSS) distribution. However, CVR is time consuming and blood flow simulation is computationally expensive, while there is no evidence that WSS computed by CVR, enables better prediction of disease progression compared to WSS derived from the conventional single vessel reconstruction (SVR). We aim to compare the WSS in models reconstructed using the CVR and SVR methods and examine its ability to predict disease progression. MethodsPatients who had baseline and 13-months follow-up intravascular ultrasound (IVUS) imaging (n=19 vessels), and with neoatherosclerotic lesions (n=13 vessels) on optical coherence tomography (OCT) were included in the present analysis. All the studied vessels had at least one side branch with diameter >1mm. 3-dimensional (3D) CVR and SVR were performed and time averaged (TAWSS) and multidirectional WSS were computed using pulsatile blood flow simulation and the performance of both methods in predicting disease progression in IVUS and OCT models were assessed. ResultsThe incorporation of side branches in 3D geometry resulted in lower TAWSS in the IVUS (0.821 vs 1.698Pa, p<0.001) and OCT-based reconstructions (0.682 vs 1.325Pa, p<0.001) and influenced the multidirectional WSS distribution. In native segments, WSS metrics estimated by the CVR enabled better prediction of the lumen and plaque area and burden at follow-up than SVR and disease progression defined as decrease in lumen area and increase in plaque burden (AUC CVR 0.712 vs SVR 0.554). In stented segments, multidirectional WSS was associated with neointima area in both CVR and SVR methods, but TAWSS was only a predictor of neointima area in the CVR method. ConclusionsThe incorporation of side branches in vessel reconstruction influences WSS distribution and enables more accurate prediction of disease progression in native and stented segments than SVR modelling. HighlightsO_LIComplete vessel reconstruction (CVR) with incorporation of vessel side branches has been proposed for accurate evaluation of wall shear stress (WSS) distribution compared to the traditional single vessel reconstruction (SVR) method; however, there are no studies comparing the performance of the WSS metrics derived by these methods in predicting atherosclerotic evolution. C_LIO_LIIn vessels with large side branches, the incorporation of the side branches in the vessel geometry reconstructed from angiographic and intravascular imaging data resulted in lower time averaged wall shear stress (TAWSS) and influenced the multidirectional WSS estimations compared to the models reconstructed without the side branches. C_LIO_LIThe WSS metrics estimated in the CVR models enabled better prediction of atherosclerotic disease progression at 13-months follow-up on IVUS than the WSS derived by the SVR. C_LIO_LIIn stented vessels, all the WSS metrics in the CVR and the multidirectional WSS in SVR were associated with neointima tissue development; however, both approaches showed limited efficacy in predicting neointima proliferation. C_LI
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Deep learning-based end-to-end automated stenosis classification and localization on catheter coronary angiography 96%
- Predicting long-term prognosis after percutaneous coronary intervention in patients with acute coronary syndromes: a prospective nested case-control analysis for county-level health services 94%
- Autologous cardiac micrografts as support therapy to coronary artery bypass surgery 93%
Similar papers in this journal
- Deep Learning-based Prediction of Early Cerebrovascular Events after Transcatheter Aortic Valve Replacement 95%
- Endovascular structures of the basilar artery: forms of the basilar nonfusion spectrum 95%
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 94%
Similar papers in this journal
- Development of a Novel Index to Characterise Arterial Dynamics Using Ultrasound Imaging 95%
- Full-field optical coherence tomography for the diagnosis of giant cell arteritis 95%
- Effects of low versus high inspired oxygen fraction on myocardial injury after transcatheter aortic valve implantation: A randomized clinical trial 93%
Similar papers in this journal
- Impact of residual intimal flap displacement post-TEVAR on TBAD haemodynamics in compliant, patient-specific CFD simulations informed by MRI 94%
- Biomechanical Characterization Of Porcine Lower Limb Arteries For Preclinical Evaluation Of Peripheral Vascular Devices 94%
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 94%
Similar papers in this journal
- Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm 95%
- Hemodynamics Indicates Differences Between Patients With And Without A Stroke Outcome After Left Ventricular Assist Device Implantation 93%
- Fluid-Structure Interactions of Peripheral Arteries Using a Coupled in silico and in vitro Approach 93%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.