Performance assessment of an electrostatic filter-diverter stent cerebrocascular protection device
Eguzkitza, B.; Navia, J.
Show abstract
Stroke is the second leading cause of death worldwide. Nearly two-thirds of strokes are produced by cardioembolisms, and half of cardioembolic strokes are triggered by Atrial Fibrillation (AF), the most common type of arrhythmia. A more recent cause of cardioembolisms is Transcatheter Aortic Valve Replacements (TAVRs), which may onset post-procedural adverse events such as stroke and Silent Brain Infarcts (SBIs), for which no definitive treatment exists, and which will only get worse as TAVRs are implanted in younger and lower risk patients. It is well known that some specific characteristics of elderly patients may lower the safety and efficacy of anticoagulation therapy, making it a real urgency to find alternative therapies. The device introduced in this paper offers an anticoagulant-free method to prevent stroke and SBIs, imperative given the growing population of AF and elderly patients. This work analyzes a design based on a patented medical device, intended to block cardioembolisms from entering the cerebrovascular system, with a particular focus on AF, and potentially TAVR patients. The study has been carried out in two stages. Both of them use computational fluid dynamics (CFD) coupled with Lagrangian particle tracking to analyse the efficacy of a novel patented medical device intended to block cardioembolisms from entering the cerebrovascular system, with a particular focus on AF, and potentially TAVR patients. The studied device consists of a strut structure deployed at the base of the treated artery. Particles of different sizes are used to model dislodged debris, which could potentially lead to cerebral embolisms if transported into these arteries. The first stage of the work evaluates a variety of strut thicknesses and inter-strut spacings, contrasting with the device-free baseline geometry. The analysis is carried out by imposing flowrate waveforms characteristic of both healthy and AF patients. Boundary conditions are calibrated to reproduce physiological flowrates and pressures in a patients aortic arch. Results from numerical simulations indicate that the device blocks particles of sizes larger than the inter-strut spacing. It was found that lateral strut space had the highest impact on efficacy. In the second stage, the optimal geometric design from the first stage was employed, with the addition of lateral struts to prevent the filtration of particles and electronegatively charged strut surfaces, studying the effect of electrical forces on the clots if they are considered charged. Flowrate boundary conditions were used to emulate both healthy and AF conditions. When deploying the electronegatively charged device in all three aortic arch arteries, the number of particles entering these arteries was reduced on average by 62.6% and 51.2%, for the healthy and diseased models respectively, matching or surpassing current oral anticoagulant efficacy. The device demonstrated a two-fold mechanism for filtering emboli: while the smallest particles are deflected by electrostatic repulsion, avoiding microembolisms, which could lead to cognitive impairment, the largest ones are mechanically filtered since they cannot fit in between the struts, effectively blocking the full range of particle sizes analyzed in this study.
Matching journals
The top 4 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- Deployment of a digital twin using the coupled momentum method for fluid-structure interaction: a case study for aortic aneurysm 97%
- Hemodynamics Indicates Differences Between Patients With And Without A Stroke Outcome After Left Ventricular Assist Device Implantation 97%
- Personalized computational hemodynamic analysis in transcatheter aortic valve: investigation of long-term degeneration 97%
Similar papers in this journal
- Effect of Sinotubular Junction Size on TAVR Leaflet Thrombosis: A Fluid-structure Interaction Analysis 98%
- Quantitative Assessment of Aortic Hemodynamics for Varying Left Ventricular Assist Device Outflow Graft Angles and Flow Pulsation 97%
- Switching the left and the right hearts: A novel bi-ventricle mechanical support strategy with spared native single-ventricle 97%
Similar papers in this journal
- Computational hemodynamic indices to identify Transcatheter Aortic Valve Implantation degeneration 96%
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part I: Establishing Credibility of an Advanced Model 95%
- In Silico Modeling of Transcatheter Heart Valve Oversizing and Ellipticity, Part II: Effects on Leaflet Mechanics, Hemodynamics, and Stent Deflection Contributing to Thrombogenic Risk and Structural Degeneration 94%
Similar papers in this journal
- A coupled atrioventricular-aortic setup for in-vitro hemodynamic study of the systemic circulation: Design, Fabrication, and Physiological relevancy 97%
- Effects of size and elasticity on the relation between flow velocity and wall shear stress in side-wall aneurysms: A lattice Boltzmann-based computer simulation study 96%
- Ventricular anatomical complexity and gender differences impact predictions from computational models 95%
Similar papers in this journal
- Understanding Embolus Transport And Source To Destination Mapping Of Thromboemboli In Hemodynamics Driven By Left Ventricular Assist Device 98%
- A 1D Model Characterizing the Role of Spatiotemporal Contraction Distributions on Lymph Transport 94%
- Investigating Clot-flow Interactions by Integrating Intravital Imaging with In Silico Modeling for Analysis of Flow, Transport, and Hemodynamic Forces. 94%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.