BackgroundRemote self-administered visual acuity (VA) tests have the potential to allow patients and non-specialists to assess vision without eye health professional input. Validation in pragmatic trials is necessary to demonstrate the accuracy and reliability of tests in relevant settings to justify deployment. MethodsA systematic review was undertaken in accordance with a preregistered protocol (CRD42022385045). The Cochrane Library, Embase, MEDLINE, and Scopus were searched. Screening was conducted according to the following criteria: (1) English languge; (2) primary research article; (3) visual acuity test conducted remotely; (4) no clinical administration of remote test; (5) accuracy or reliability of remote test analysed. There were no restrictions on trial participants. Quality assessment was conducted with QUADAS-2. ResultsOf 1227 identified reports, 10 studies were ultimately included. One study was at high risk of bias and two studies exhibited concerning features of bias; all studies were applicable. Three trials--of DigiVis, iSight Professional, and Peek Acuity--from two studies suggested that accuracy of the remote tests was comparable to clinical assessment. All other trials exhibited inferior accuracy, including conflicting results from a pooled study of iSight Professional and Peek Acuity. Two studies evaluated test-retest agreement--one trial provided evidence that DigiVis is as reliable as clinical assessment. The three most accurate tests required access to digital devices. Reporting was inconsistent and often incomplete, particularly with regards to describing methods and conducting statistical analysis. ConclusionsRemote self-administered VA tests appear promising, but further pragmatic trials are indicated to justify deployment at scale to facilitate patient or non-specialist led assessment which could augment teleophthalmology, non-specialist eye assessment, pre-consultation triage, and autonomous long-term monitoring of vision.

Matching journals

The top 3 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.