Artificial intelligence for automated thoracic aorta diameter measurement using different computed tomography protocols
Portugal, M. F. C.; Pinheiro, L. L.; Lee, H. M. H.; Vieira, H. C.; de Oliveira, L. L.; del Valle, M.; Miyoshi, N. S. B.; Oliveira-Ciabati, L.; Baroni, R.; Szarf, G.; Wolosker, N.
Show abstract
IntroductionThoracic aortic aneurysm diameter determination is paramount for the decision-making process regarding surgical management. Studies focusing in asymptomatic patients have determined prevalence of 0.16 to 0.36% of TAAs in imaging studies. Several groups have proposed automated aortic measurement tools as propaedeutic and therapeutic instruments. In this study we developed and tested an automatic 3-dimensional (3D) segmentation method for the thoracic aorta, applicable on computed tomography angiography (CTA) acquired using low-dose and standard dose protocol, with and without contrast enhancement; and to accurately calculate the 3D diameter information of the arterial segments. Methodsa retrospective cohort of all CT scans acquired in our service between 2016 and 2021 led to the selection of 587 CT exams including low and standard-dose radiation, with and without contrast enhancement. 527 exams were used for neural network training of an algorithm capable of aptly measuring the aortic diameters, using manual measurements performed by three medical specialists as a baseline. Sixty exams were used for validation. The algorithm was developed both for use with the support of PyRadiomics and for a self-made approach. ResultsAortic measurement using the algorithm supported by PyRadiomics resulted in mean absolute error values under 2mm. For the self-made approach, mean absolute error values were under 5mm. ConclusionThis study presents an effective automated solution for thoracic aortic measurement with good results in sets of standard or low-radiation exams, as well as those acquired with or without contrast enhancement; presenting a possibility for an auxiliary tool for automation of the process of measuring the diameter of the thoracic aorta.
Matching journals
The top 5 journals account for 50% of the predicted probability mass.
Similar papers in this journal
- AngioNet: A Convolutional Neural Network for Vessel Segmentation in X-ray Angiography 96%
- Evaluation of the second-generation whole-heart motion correction algorithm (SSF2) used to demonstrate the aortic annulus on cardiac CT 96%
- Inconsistency of AI in Intracranial Aneurysm Detection with Varying Dose and Image Reconstruction 94%
Similar papers in this journal
- Fully Automated Explainable Abdominal CT Contrast Media Phase Classification Using Organ Segmentation and Machine Learning 94%
- Phase Recognition in Contrast-Enhanced CT Scans based on Deep Learning and Random Sampling 93%
- Selective ensemble methods for deep learning segmentation of major vessels in invasive coronary angiography 93%
Similar papers in this journal
Similar papers in this journal
- Development of a Novel Index to Characterise Arterial Dynamics Using Ultrasound Imaging 96%
- Enhancing Semantic Segmentation in Chest X-Ray Images through Image Preprocessing: ps-KDE for Pixel-wise Substitution by Kernel Density Estimation 93%
- ai-corona : Radiologist-Assistant Deep Learning Framework for COVID-19 Diagnosis in Chest CT Scans 92%
Similar papers in this journal
- Auto-detection of motion artifacts on CT pulmonary angiograms with a physician-trained AI algorithm 94%
- Detection, Isolation and Quantification of Myocardial Infarct with Four Different Histological Staining Techniques 92%
- A Machine Learning Ensemble Based on Radiomics to Predict BI-RADS Category and Reduce the Biopsy Rate of Ultrasound-Detected Suspicious Breast Masses 90%
"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.