Validity of gait parameters of healthy young adults using a motion-sensor-based gait analysis system (ORPHE ANALYTICS) during walking and running

Uno, Y.; Ogasawara, I.; Konda, S.; Yoshida, N.; Tsujii, A.; Nakata, K.

2022-10-17 rehabilitation medicine and physical therapy
10.1101/2022.10.17.22281166 medRxiv
Show abstract

BackgroundMotion sensors are widely used for gait analysis. ORPHE ANALYTICS is a motion-sensor-based gait analysis system. The validity of commercial gait analysis systems is of great interest to clinicians because calculating position/angle-level gait parameters using motion sensor data potentially produces an error in the integration process; moreover, the validity of ORPHE ANALYTICS has not yet been examined. Research questionHow valid are the position/angle-level gait parameters calculated using ORPHE ANALYTICS relative to those calculated using conventional optical motion capture? MethodsNine young adults performed gait tasks on a treadmill at speeds of 2-12 km/h. The motion sensors were mounted on the shoe midsole (plantar-embedded) and shoe instep (instep-mounted). The three-dimensional marker position data of the foot as well as the acceleration and angular velocity data of the motion sensors were collected. The position/angle-level gait parameters were calculated from motion sensor data obtained using ORPHE ANALYTICS and optical motion capture data. Intraclass correlation coefficients [ICC(2,1)] were calculated for relative validities, and Bland-Altman plots were plotted. ResultsEight items, namely, stride duration, stride length, stride frequency, stride speed (plantar-embedded), vertical height (plantar-embedded), stance phase duration, swing phase duration, and sagittal angleIC, exhibited excellent relative validities [ICC(2,1) > 0.9]. In contrast, the sagittal angleTO demonstrated good relative validity [ICC(2,1) = 0.892-0.833], while the frontal angleIC exhibited moderate relative validity [ICC(2,1) = 0.566-0.627]. SignificanceORPHE ANALYTICS, a motion-sensor-based gait analysis system, was found to exhibit excellent relative validity for most gait parameters. This finding suggests its feasibility for gait analysis outside the laboratory setting. HighlightsO_LIGait-parameter validities were examined for treadmill-based gait tasks at 2-12 km/h. C_LIO_LIMost gait parameters showed excellent relative validity with optical motion capture. C_LIO_LIShoe midsole-embedded sensors had higher validities than instep-mounted sensors. C_LIO_LIORPHE ANALYTICS is potentially useful in clinical measurements. C_LI

Matching journals

The top 2 journals account for 50% of the predicted probability mass.

50% of probability mass above

"Similar papers" are the closest papers from that journal in the model's embedding space. They show what the match is built on, but the ranking comes mostly from a classifier over the whole training set, not from these examples alone.